Distal femoral cut in total knee arthroplasty in a Brazilian population☆

نویسندگان

  • Marcos Areias Vieira Costa
  • Alan de Paula Mozella
  • Hugo Alexandre de Araujo Barros Cobra
چکیده

OBJECTIVE To determine the ideal angle for making the distal femoral cut in total knee arthroplasty in a Brazilian population. METHODS Panoramic radiographs of the lower limbs bearing weight from 79 patients (57 women and 22 men) were studied, totaling 107 knees with an indication for total knee arthroplasty. The femoral anatomical axis, femoral mechanical axis and cervical-diaphyseal angle were traced out. The angle of the femoral cut was determined from the meeting point between the femoral anatomical and mechanical axes. The ideal degree of femoral valgus was compared between men and women and between knees presenting varus and valgus alignment of the lower limb. The ideal distal femoral cut was also correlated with the cervical-diaphyseal angle. RESULTS The ideal femoral valgus angle ranged from 4.2 to 8.6 degrees, with a mean of 6.3 degrees. There was no statistically significant difference in the distal femoral cut between patients with coronal varus and valgus alignment (p = 0.180). Comparing men and women, there was no statistically significant difference regarding the ideal femoral valgus between the groups (p = 0.057). The cervical-diaphyseal angle presented an inverse relationship with the distal femoral cut. CONCLUSIONS The mean angle between the femoral mechanical and anatomical axes was 6.3 degree. Neither preoperative coronal alignment nor sex had any influence on the distal femoral cut. The cervical-diaphyseal angle presented an inverse relationship with the distal femoral cut.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Distal Femoral Valgus Cut Errors in Total Knee Replacement

The causes of malalignment in total knee arthroplasty can be categorized into three different groups; 1) Errors in bone cuts 2) Errors in implant fixations, and 3) The method of setting down the cutting guides (1). We would like to announce that more several distal femoral valgus cut errors may occur during total knee replacement.

متن کامل

Anthropometric Measurements of Distal Femur to Design the Femoral Component of Total Knee Arthroplasty for the Iranian Population

Background: Acquiring knowledge about anatomic and geometric quantities of bones is among the most vitalparameters in orthopedic surgery that has a significant effect on the treatment of various disorders and subsequentoutcomes. The aim of this study was to obtain anthropometric information for distal femur in order to compare withsimilar dimensions of prosthesis used in total...

متن کامل

Different References for Valgus Cut Angle in Total Knee Arthroplasty

Background: The valgus cut angle (VCA) of the distal femur in Total Knee Arthroplasty (TKA) is measured preoperativelyon three-joint alignment radiographs. The anatomical axis of the femur can be described as the anatomical axis of thefull length of the femur or as the anatomical axis of the distal half of the femur, which may result in different anglesin some cases. During TKA, the anatomical ...

متن کامل

Radiologic Assessment of Distal Femur Cutting Angle in Varus Knee Candidates for Total Knee Arthroplasty

Background: In a total knee arthroplasty surgery the goal is to produce 90 degree angle between the knee articular lobe and the mechanical femoral line. Most orthopedic surgeons usually utilize a 5 to 7 degree for distal femoral cutting angle. In this study we will aim at clearing this question, that whether the” five-seven degree” distal femoral cutting angle supposed to be an equable spectrum...

متن کامل

Evaluation of Distal Femoral Rotational Alignment with Spiral CT Scan before Total Knee Arthroplasty (A Study in Iranian Population)

    Background: Evaluating the landmarks for rotation of the distal femur is a challenge for orthopedic surgeons. Although the posterior femoral condyle axis is a good landmark for surgeons, the surgical transepicondylar axis may be a better option with the help of preoperative CT scanning. The purpose of this study was to ascertain relationships among the axes’ guiding distal femur rotational ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 50  شماره 

صفحات  -

تاریخ انتشار 2015