On the Various Time Constants of Wavelength Changes of a DFB Laser Under Direct Modulation
نویسندگان
چکیده
The temporal behavior of the optical frequency emitted by several DFB lasers under direct square wave modulation was measured using an all-fiber implementation of a Mach–Zender interferometer with an imbalance of 30 ps. The impulse response of the optical frequency to injection current modulation was found to contain a time constant as short as 10–20 ns, together with a few longer ones. The existence of such a short time constant is consistent with a thermal analysis of a laser structure with finite thermal impedance of the active region and should be taken into consideration in various wide bandwidth applications of direct modulated semiconductor lasers.
منابع مشابه
Field detection of CO and CH4 by NIR 2f modulation laser spectroscopy
A novel compact fiber-coupled NIR system based on a DFB diode laser source is employed as a portable and sensitive gas sensor for trace detection of combustion pollutant molecules. We demonstrate the performance of such an NIR gas sensor by tracing the absorption lines of CO and CH4 using 2f-WMS technique at moderate temperature of T ~ 600°C in the recuperator channel of an industrial furnace...
متن کاملThe Effects of Strained Multiple Quantum Well on the Chirped DFB-SOA All Optical Flip-Flop
In this paper, based on the coupled-mode and carrier rate equations, a dynamic model and numerical analysis of a multi quantum well (MQW) chirped distributed feedback semiconductor optical amplifier (DFB-SOA) all-optical flip-flop is precisely derived. We have analyzed the effects of strains of QW and MQW and cross phase modulation (XPM) on the dynamic response, and rise and fall times of the ...
متن کاملFast Wavelength-Switching of Laser Transmitters and Amplifiers
This paper discusses system aspects and describes experimental demonstrations of nanosecond wavelength tuning in laser diode structures. Both tunable transmitters and tunable filters are considered. The dependence of the refractive index on the carrier density in semiconductors is exploited to obtain fast wavelength tuning. Experimentally, switching times of < 15 ns have been demonstrated in a ...
متن کاملRecent Advances in Trace Gas Detection Using Quantum and Interband Cascade Lasers
There is an increasing need in many chemical sensing applications ranging from environmental science to industrial process control as well as medical diagnostics for fast, sensitive, and selective trace gas detection based on laser spectroscopy. The recent availability of novel pulsed and continuous wave (cw) quantum and interband cascade distributed feedback (QC and IC DFB) lasers as mid-infra...
متن کاملA Time Difference Method for Measurement of Phase Shift between Distributed Feedback Laser Diode (DFB-LD) Output Wavelength and Intensity
A time difference method to conveniently measure the phase shift between output wavelength and intensity of distributed feedback laser diodes (DFB-LDs) was proposed. This approach takes advantage of asymmetric absorption positions at the same wavelength during wavelength increase and decrease tuning processes in the intensity-time curve by current modulation. For its practical implementation, a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید