Rotating analyzer–fixed analyzer ellipsometer based on null type ellipsometer
نویسنده
چکیده
The theory and design of an inexpensive rotating analyzer unit is presented, which allows a conventional null type ellipsometer to work as rotating analyzer–fixed analyzer automatic ellipsometer, without sacrificing the possibility to work in null mode. The mode switching is performed simply by adding or removing the rotating analyzer from its holder. It is shown that the rotating analyzer phase shift in rotating analyzer–fixed analyzer mode can be run-time determined from the measured Fourier coefficients. This avoids any need of recalibration procedure after mode switching and makes unnecessary plane of incidence synchronization, which further simplifies the needed hardware and reduces the errors connected with the phase shift instability of the output signal. The run-time phase shift calibration procedure and subsequent ellipsometric angles determination do not involve normalization of the output signal Fourier coefficients to the zeroth harmonic, eliminating in this way the influence of the dc component time drift. © 1999 American Institute of Physics. @S0034-6748~99!01807-9#
منابع مشابه
Ellipsometer nulling: convergence and speed.
The process of nulling in ellipsometry is studied by a graphical presentation using the trajectories of two significant polarization states in the complex plane, (XPC) and (XSA). These states are determined by (1) the polarizer and compensator ((XPC)) and (2) the specimen and the analyzer ((XSA)) in the polarizer-compensator-specimen-analyzer ellipsometer arrangement. As the azimuth angles of t...
متن کاملSynchrotron radiation-based far-infrared spectroscopic ellipsometer with full Mueller-matrix capability.
We developed far-IR spectroscopic ellipsometer at the U4IR beamline of the National Synchrotron Light Source in Brookhaven National Laboratory. This ellipsometer is able to measure both, rotating analyzer and full-Mueller matrix spectra using rotating retarders, and wire-grid linear polarizers. We utilize exceptional brightness of synchrotron radiation in the broad spectral range between about ...
متن کاملThe Applications of the Heterodyne Interferoemetry
Optical interferometry is widely used in many precision measurements such as displacement[1, 2], vibration[3, 4], surface roughness[5, 6], and optical properties[7-14] of the object. For example, holographic interferomter [1-3] can be used to measure the surface topography of the rigid object. The emulsion side of the photographic plate faces the object and is illuminated by a plane wave at nor...
متن کاملC4an01853b 1791..1797 ++
Fast infrared mapping with sub-millimeter lateral resolution as well as time-resolved infrared studies of kinetic processes of functional organic thin films require a new generation of infrared ellipsometers. We present a novel laboratory-based infrared (IR) laser mapping ellipsometer, in which a laser is coupled to a variableangle rotating analyzer ellipsometer. Compared to conventional Fourie...
متن کاملZone-averaged method to minimize polarizer and analyzer imperfections in a phase-modulated spectroscopic ellipsometer
We have theoretically investigated the effects of polarizer and analyzer imperfections in a phase-modulated spectroscopic ellipsometer adopting a photoelastic modulator. Jones matrices having off-diagonal elements have been introduced to represent the imperfections of the polarizer and analyzer, and the effects of the imperfections were analytically derived to the first-order approximation. It ...