Quantification of left ventricular mechanical dyssynchrony by conductance catheter in heart failure patients.
نویسندگان
چکیده
Mechanical dyssynchrony is an important codeterminant of cardiac dysfunction in heart failure. Treatment, either medical, surgical, or by pacing, may improve cardiac function partly by improving mechanical synchrony. Consequently, the quantification of ventricular mechanical (dys)synchrony may have important diagnostic and prognostic value and may help to determine optimal therapy. Therefore, we introduced new indexes to quantify temporal and spatial aspects of mechanical dyssynchrony derived from online segmental conductance catheter signals obtained during diagnostic cardiac catheterization. To test the feasibility and usefulness of our approach, we determined cardiac function and left ventricular mechanical dyssynchrony by the conductance catheter in heart failure patients with intraventricular conduction delay (n = 12) and in patients with coronary artery disease (n = 6) and relatively preserved left ventricular function. The heart failure patients showed depressed systolic and diastolic function. However, the most marked hemodynamic differences between the groups were found for mechanical dyssynchrony, indicating a high sensitivity and specificity of the new indexes. Comparison of conductance catheter-derived indexes with septal-to-lateral dyssynchrony derived by tissue-Doppler velocity imaging showed highly significant correlations. The proposed indexes provide additional, new, and quantitative information on temporal and spatial aspects of mechanical dyssynchrony. They may refine diagnosis of cardiac dysfunction and evaluation of interventions, and ultimately help to select optimal therapy.
منابع مشابه
Impact of Phase Analysis of Gated SPECT to Assessment of Left Ventricular Mechanical Dyssynchrony in Diabetic Patients with Normal MPI
Objective: Diabetes mellitus is an important cause of heart failure deployment of left ventricular mechanical dyssynchrony. Nuclear cardiology phase analysis is an accurate, repeatable and reproducible modality for measurement LV dyssynchrony .The aim of study was assessment of phase analysis parameter including Standard deviation (SD) and band width (BW) in diabetic patient with normal MPI com...
متن کاملThe associations between tricuspid annular plane systolic excursion (TAPSE), ventricular dyssynchrony, and ventricular interaction in heart failure patients.
AIMS Ventricular interactions may be mediated by loading conditions and biventricular timing and coordination. We sought to understand the relationships between right (RV) and left ventricular (LV) function and dyssynchrony, examine the RV correlates of LV dyssynchrony, and determine whether improved loading conditions affect inter-ventricular interaction. METHODS AND RESULTS In 25 heart fail...
متن کاملClinical Assessment and Implication of Left Ventricular Mechanical Dyssynchrony in Patients with Heart Failure.
UNLABELLED There have been numerous studies focusing on the assessment of left ventricular mechanical dyssynchrony. These studies are diverse in their purposes, which include more effectively predicting the response to cardiac resynchronization therapy, improving the guidance of the left ventricular lead position, and better prediction of outcome in patients with heart failure. This article rev...
متن کاملInterventricular and intraventricular dyssynchrony are common in heart failure patients, regardless of QRS duration.
AIMS The study aimed at evaluating the prevalence of interventricular and intraventricular contractile dyssynchrony in heart failure patients with either normal or prolonged QRS duration. METHODS AND RESULTS Echocardiography and tissue Doppler imaging (TDI) were performed in 158 consecutive patients with advanced left ventricular dysfunction (LVEF<35%); 61 patients had a normal QRS duration (...
متن کاملAssociation of intraventricular mechanical dyssynchrony with response to cardiac resynchronization therapy in heart failure patients with a narrow QRS complex
AIMS current criteria for cardiac resynchronization therapy (CRT) are restricted to patients with a wide QRS complex (>120 ms). Overall, only 30% of heart failure patients demonstrate a wide QRS complex, leaving the majority of heart failure patients without this treatment option. However, patients with a narrow QRS complex exhibit left ventricular (LV) mechanical dyssynchrony, as assessed with...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- American journal of physiology. Heart and circulatory physiology
دوره 286 2 شماره
صفحات -
تاریخ انتشار 2004