Nonlinear Control of Single-Phase Shunt Active Power filter Theoretical analysis of closed-loop performances

نویسندگان

  • I. Lachkar
  • F. Giri
  • A. Abouloifa
  • J. M. Guerrero
  • H. Elfadil
چکیده

The problem of controlling single-phase shunt active power filter is addressed in presence of nonlinear loads. The control objective is twofold: (i) compensation of harmonic and reactive currents absorbed by the nonlinear load; (ii) regulation of the inverter output capacitor voltage. A two-loop cascade control strategy is developed that includes an inner-loop designed, using the backstepping technique, to cope with the compensation issue and an outer-loop designed to regulate the capacitor voltage. The controller performances are formally analysed, using the averaging theory. The analysis results are illustrated by simulation. 

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Indirect Control of Single-Phase Active Power Filters using Harmonic Control Arrays

The ever increase of nonlinear loads in electric distribution networks causes many problems due to the high level of harmonic currents. This paper proposes a new technique for controlling a single phase shunt active power filter based on a selective compensation using the newly developed technique of harmonic control arrays. Simulation results confirm the appropriate selective harmonic compensa...

متن کامل

طراحی کنترل‌کننده دو حلقه‌ای برای فیلتر فعال تک فاز موازی بدون سنسور با خروجی LCL با در نظر گرفتن تأخیر محاسبات و مدولاسیون

This paper presents a new approach for single-phase shunt active power filter with LCL output filter based on the two-loop control theory. In this method unlike the conventional two loop control, internal loop stability theorem with considering delay effect is studied. Moreover, an observer based on the Kalman-filter is combined with the proposed control scheme, to reducing the numbers of power...

متن کامل

Active Filter Control Method Based on Direct Power Control for Compensating Reactive Powers due to Unbalanced Voltages and Nonlinear Loads

Active filters have proven to be more effective than passive techniques to improve power quality and to solve harmonic and power factor problems due to nonlinear loads. This paper proposes a control scheme based on the instantaneous active and reactive power. The inverter of this active filter is a three-phase, two-level converter. Space vector technique is used as modulators and pattern genera...

متن کامل

A Hybrid Control Method for Stable Operation of Active Power Filters in Three-Phase Four-Wire Networks

The main goal of this study is the use of Lyapunov’s stability theory to a three-phase four-wire shunt active power filter (SAPF), since this method has been applied effectively to other areas of converter. The dynamic model of the SAPF is first established, after that, a combination of fuzzy tracking control and Lyapunov function is suggested in order to impose a desired transient waveform on ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2011