Effect of hemodialysis on blood volume distribution and cardiac output.

نویسندگان

  • M Chaignon
  • W T Chen
  • R C Tarazi
  • E L Bravo
  • S Nakamoto
چکیده

Effects of hemodialysis on extracellular fluid volume distribution, left ventricular volumes, and cardiac output were determined in patients with end-stage renal disease (n = 19). Distribution of extracellular fluid loss from hemodialysis differed widely among patients, so that weight change correlated weakly with contraction of total blood volume (index of determination 29%, p less than 0.05). End-diastolic volume (EDV) decreased from 150 +/- 49 ml (mean +/- SD) to 118 +/- 42 ml, p less than 0.001; stroke volume (SV) decreased from 108 +/- 36 to 86 +/- 33 ml (p less than 0.001) without change in ejection fraction (from 0.73 +/- 0.09 to 0.74 +/- 0.11). A significant correlation was found between total blood volume (TBV) and EDV before (r = 0.66, p less than 0.005) and after dialysis (r = 0.61, p less than 0.001). The correlation between TBV and SV was highly significant before (r = 0.78, p less than 0.001) and after dialysis (r = 0.66, p less than 0.005), but there was no correlation between change in TBV and change in EDV or in SV. The ratio of EDV to TBV (EDV/TBV x 100) was reduced significantly from 3.49 +/- 0.92 to 3.06 +/- 0.97, p less than 0.001). There results suggest that, although intravascular volume was the major determinant of cardiac output in dialyzed patients, the postdialysis reduction in cardiac output might be related more to the relocation of blood volume than to the absolute degree of blood volume contraction.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A System for Continuous Estimating and Monitoring Cardiac Output via Arterial Waveform Analysis

Background: Cardiac output (CO) is the total volume of blood pumped by the heart per minute and is a function of heart rate and stroke volume. CO is one of the most important parameters for monitoring cardiac function, estimating global oxygen delivery and understanding the causes of high blood pressure. Hence, measuring CO has always been a matter of interest to researchers and clinicians. Sev...

متن کامل

Effects of the Intermittent Pneumatic Circulator on Blood Pressure during Hemodialysis

Hypotension is frequently reported during hemodialysis. This study aimed to examine the effect of the intermittent pneumatic circulator on blood pressure during hemodialysis. Sixteen subjects with chronic hemodialysis were recruited. Each subject randomly received two test conditions on separate days, hemodialysis with and without the circulator. The circulator was applied to the subject on low...

متن کامل

Optimized Blood Volume Monitoring during Hemodialysis Procedure based on Ultrasonic Speed Measurement

Fast reduction of blood water volume due to ultra-filtration via hemodialysis machine and critical threshold of blood water volume can result in clinical complications such as hypotension. When blood water volume reduces during hemodialysis process, the concentration of blood forming elements will increase. One of the methods for the monitoring of the concentration changes is ultrasonic speed m...

متن کامل

بررسی اثر درشت مغذی‌ها بر پاسخ‌های قلبی - عروقی در افراد سالم و دیابتی نوع II

Introduction: It is felt that there is an information void regarding the effect of macronutrients on cardiovascular responses such as cardiac output,heart rate,stroke volume,systolic blood pressure,diastolic blood pressure and mean arterial pressure, therefore, this study was designed to explore these effects at Shaheed Beheshti University in 2001. Materials & Methods: This clinical trial was ...

متن کامل

Blood pressure response to hemodialysis.

Blood pressure response to hemodialysis was investigated in 15 patients with end-stage kidney disease; mean arterial pressure was unchanged in five (Group 1) and reduced 10 mm Hg in 10 (Group 2). The two groups did not differ significantly with regard to either biochemical values or hemodynamic indices before dialysis, and both sustained comparable reduction in body weight, total blood volume, ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Hypertension

دوره 3 3  شماره 

صفحات  -

تاریخ انتشار 1981