Optimisation of device clocking schemes to minimise the effects of radiation damage in Charge Coupled Devices
نویسندگان
چکیده
The ESA Euclid mission aims to answer the question of how the universe originated through the mapping of the dark Universe. One method to investigate this geometry is to measure subtle changes in ellipticity using image sensors such as the CCD. However, the radiation environment in space plays a major part in the performance of CCD-based camera systems. When placed in space, a CCD becomes damaged by the radiation environment and this can lead to a ‘smearing’ of the charge, acting to change the ellipticity and therefore one must be able to separate the changes in ellipticity caused by radiation damage from those the mission aims to measure. To this end, the radiation damage induced shape changes require in depth investigation such that optimised operation can be achieved. A Monte Carlo simulation is being used to predict this impact, backed by experimental data from a detector formerly baselined for the mission. During the experimental study, an investigation was undertaken into the serial readout of the CCD to demonstrate an approach towards performance optimisation through a consideration of the trap species involved. A change in clocking scheme was found to result in a factor of three reduction in Charge Transfer Inefficiency.
منابع مشابه
Charge Transfer in Overlapping Gate Charge-Coupled Devices
A detailed numerical simulation of the free charge trsnrfer in overlapped gate charge-coupled devices (CCD) is presented. The transport dynamics are analyzed in terms of thermal diffusion, self-induced fields, and fringing fields under all the relevant electrodes and the interelectrode regions with time-varying gate potentials. The results of the charge trmwfer with clifferent clocking schemes ...
متن کاملRadiation Damage E ects in CCD Sensors for Tracking Applications in High Energy Physics Ph.D. Thesis
This thesis presents systematic studies on the radiation damage e ects in 2and 3-phase Charge Coupled Devices (CCD). CCDs are one of the primary options for tracking devices at the vertex detector of a future Linear Collider due to their high precision and twodimensional resolution. The radiation backgrounds near the interaction point impose considerable challenge to the tolerance of the CCD se...
متن کاملمقایسه سنسورهای دیجیتالی Charge-Coupled Device با Photostimulable Phosphor Storage Plate در تشخیص شکستگی عمودی ریشه در دندانهای اندو شده (مطالعه آزمایشگاهی)
Objective: Vertical root fracture (VRF) is among the most common causes of endodontic treatment failures. This study aims to compare charge-coupled devices (CCD) and photostimulable phosphor plates (PSP) for detection of vertical root fractures in endodontically treated teeth. Methods: In this diagnostic in vitro study, 40 maxillary anterior teeth were selected and after preparation and roo...
متن کاملModelling charge transfer in a radiation damaged Charge Coupled Device for Euclid
As electrons are transferred through a radiation damaged Charge Coupled Device (CCD), they may encounter traps in the silicon in which they will be captured and subsequently released. This capture and release of electrons can lead to a ‘smearing’ of the image. The dynamics of the trapping process can be described through the use of Shockley-Read-Hall theory, in which exponential time constants ...
متن کاملDevelopment of an Advanced Optical Coherence Tomography System for Radiation Dosimetry
Introduction: According to the literature, optical coherence tomography (OCT) can be used measure radiation absorbed dose. This study was carried out to design a computed tomography system for the calculation of absorbed dose and optimization of dose delivery in radiotherapy using gel dosimeters. Material and Methods: An advanced charge-coupled device based OCT system was developed in laborator...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2013