Evaluation of cleaning and disinfection performance of automatic washer disinfectors machines in programs presenting different cycle times and temperatures.
نویسنده
چکیده
Thermal washer-disinfectors represent a technology that brought about great advantages such as, establishment of protocols, standard operating procedures, reduction in occupational risk of a biological and environmental nature. The efficacy of the cleaning and disinfection obtained by automatic washer disinfectors machines in running programs with different times and temperatures determined by the different official agencies was validated according to recommendations from ISO Standards 15883-1/1999 and HTM2030 (NHS Estates, 1997) for the determining of the Minimum Lethality and DAL both theoretically and through the use with thermocouples. In order to determine the cleaning efficacy, the Soil Test, Biotrace Pro-tect and the Protein Test Kit were used. The procedure to verify the CFU count of viable microorganisms was performed before and after the thermal disinfection. This article shows that the results are in compliance with the ISO and HTM Standards. The validation steps confirmed the high efficacy level of the Medical Washer-Disinfectors. This protocol enabled the evaluation of the procedure based on evidence supported by scientific research, aiming at the support of the Supply Center multi-professional personnel with information and the possibility of developing further research.
منابع مشابه
Computer-aided recording of automatic endoscope washing and disinfection processes as an integral part of medical documentation for quality assurance purposes
BACKGROUND The reprocessing of medical endoscopes is carried out using automatic cleaning and disinfection machines. The documentation and archiving of records of properly conducted reprocessing procedures is the last and increasingly important part of the reprocessing cycle for flexible endoscopes. METHODS This report describes a new computer program designed to monitor and document the auto...
متن کاملDutch surveys bedpan management (1990 & 2010): progress in correct use of washer disinfectors
Introduction / objectives In the Netherlands bedpans are regarded as semi-critical items unlike Spauldings scheme (1968), where bedpans are categorized as non-critical items. Washer-disinfectors (WD) were used incorrect for a long time. A survey in 1990 showed poor final cleaning and disinfection results. The Dutch Working Party Infection Prevention made guidelines for WD (1998), and in 2006 th...
متن کاملGlutaraldehyde-resistant Mycobacterium chelonae from endoscope washer disinfectors.
Glutaraldehyde is used to disinfect flexible and other heat-sensitive endoscopes often with the aid of automated systems. Mycobacterium chelonae is being isolated with increasing frequency from these washer disinfectors and processed endoscopes. This has, on occasions, led to misdiagnosis and iatrogenic infections. Recent reports suggest that disinfecting machines, on a sessional or regular bas...
متن کاملAn evaluation of washer-disinfectors (WD) and dishwashers (DW) effectiveness in terms of processing dental instruments.
PURPOSE The aim of this study is to consider the effectiveness of a small sample of dishwashers (DW) compared to washer-disinfectors (WD) for cleaning dental instruments prior to sterilisation. Processing instruments in the context of this article means cleaning and disinfecting the instruments. MATERIALS AND METHODS A number of tests were carried out on three domestic dishwashers and two ins...
متن کاملThe importance of cleaning for the overall results of processing endoscopes.
Reprocessing comprises three steps: cleaning, disinfection and-if required-sterilisation. While the extents of disinfection and of sterilisation are quantitatively defined, there are only imprecise (qualitative) definitions of cleaning. There are two main reasons for accurate cleaning. First organic and inorganic materials that remain on inner and outer surfaces will interfere with the efficacy...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Revista latino-americana de enfermagem
دوره 14 5 شماره
صفحات -
تاریخ انتشار 2006