Detection of Escherichia coli in biofilms from pipe samples and coupons in drinking water distribution networks.

نویسندگان

  • T Juhna
  • D Birzniece
  • S Larsson
  • D Zulenkovs
  • A Sharipo
  • N F Azevedo
  • F Ménard-Szczebara
  • S Castagnet
  • C Féliers
  • C W Keevil
چکیده

Fluorescence in situ hybridization (FISH) was used for direct detection of Escherichia coli on pipe surfaces and coupons in drinking water distribution networks. Old cast iron main pipes were removed from water distribution networks in France, England, Portugal, and Latvia, and E. coli was analyzed in the biofilm. In addition, 44 flat coupons made of cast iron, polyvinyl chloride, or stainless steel were placed into and continuously exposed to water on 15 locations of 6 distribution networks in France and Latvia and examined after 1 to 6 months exposure to the drinking water. In order to increase the signal intensity, a peptide nucleic acid (PNA) 15-mer probe was used in the FISH screening for the presence or absence of E. coli on the surface of pipes and coupons, thus reducing occasional problems of autofluorescence and low fluorescence of the labeled bacteria. For comparison, cells were removed from the surfaces and examined with culture-based or enzymatic (detection of beta-d-glucuronidase) methods. An additional verification was made by using PCR. Culture method indicated presence of E. coli in one of five pipes, whereas all pipes were positive with the FISH methods. E. coli was detected in 56% of the coupons using PNA FISH, but no E. coli was detected using culture or enzymatic methods. PCR analyses confirmed the presence of E. coli in samples that were negative according to culture-based and enzymatic methods. The viability of E. coli cells in the samples was demonstrated by the cell elongation after resuscitation in low-nutrient medium supplemented with pipemidic acid, suggesting that the cells were present in an active but nonculturable state, unable to grow on agar media. E. coli contributed to ca. 0.001 to 0.1% of the total bacterial number in the samples. The presence and number of E. coli did not correlate with any of physical and/or chemical characteristic of the drinking water (e.g., temperature, chlorine, or biodegradable organic matter concentration). We show here that E. coli is present in the biofilms of drinking water networks in Europe. Some of the cells are metabolically active but are often not detected due to limitations of traditionally used culture-based methods, indicating that biofilm should be considered as a reservoir that must be investigated further in order to evaluate the risk for human health.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

ارزیابی توانایی کلستریدیوم پرفرنژنس در تعیین آلودگی مدفوعی آب در مقایسه با باکتری های شاخص

Introduction & Purpose Fecal coliforms and Escherichia coli have been conventionally used as indicators of microbial pollution of drinking water. The European Directive on drinking water quality has included Clostridium perfringens as one of the microbiological parameters to be determined in control of the water quality for human consumption. This study was carried out to evaluate the efficien...

متن کامل

Detection, integration and persistence of aeromonads in water distribution pipe biofilms.

The occurrence of Aeromonas spp. within biofilms formed on stainless steel (SS), unplasticized polyvinyl chloride (uPVC) and glass (GL) substrata was investigated in modified Robbins Devices (MRD) in potable (MRD-p) and recycled (MRD-r) water systems, a Biofilm Reactor (BR) and a laboratory-scale pipe loop (PL) receiving simulated recycled wastewater. No aeromonads were isolated from the MRD-p ...

متن کامل

Biofilm formation in surface and drinking water distribution systems in Mafikeng, South Africa

Poor quality source water and poorly treated reused wastewater may result in poor quality drinking water that has a higher potential to form biofilms. A biofilm is a group of microorganisms which adhere to a surface. We investigated biofilm growth in the drinking water distribution systems in the Mafikeng area, in the NorthWest Province of South Africa. Analysis was conducted to determine the p...

متن کامل

The relation of water contamination and Colibacillosis occurrence in poultry farms in Qom province of Iran

Seventy poultry farms’ drinking water was tested for Escherichia coli contamination in Qom province inIran. The cases of colibacillosis from positive farms were also collected and tested. The isolates wereexamined for serotype, detection of virulence genes by multiplex PCR and antibiotic resistance. Thirtypoultry farm water samples were E. coli positive (18.57%), although 13 E. coli isolates we...

متن کامل

Gastroenteritis Outbreak Related to Drinking Water Consumption in A Rural Area of Khuzestan Province

Background and Objectives: In June 2018 , 537 residents of a rural area in Khuzestan Province presented to the regional Comprehensive Health Service Center for gastroenteritis symptoms. This study was designed to determine the extent and cause of the outbreak.   Methods: A case-control study was performed after random selection of the case and control groups (80 cases and 88 controls). Clinic...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Applied and environmental microbiology

دوره 73 22  شماره 

صفحات  -

تاریخ انتشار 2007