Upright and Supine Positions
نویسنده
چکیده
Left ventricular (LV) performance at rest and during multilevel exercise in the supine and upright positions was studied in seven normal subjects with equilibrium radionuclide ventriculography. The mean left ventricular end-diastolic volume (LVEDV) during supine rest was 107 4 10 ml (± SEM) and 85 ± 6 ml (p < 0.02) in the upright position; the mean resting left ventricular end-systolic volumes (LVESV) were not diSferent in the upright and supine positions. The LV ejection fraction (LVEF) tended to be slightly higher in the supine (76 ± 2%) than in the upright position (72 4%). The resting hpart rate was 89 + 5 beats/min upright, compared with 71 ± 6 beats/min supine (p < 0.05). Multilevel exercise testing was carried out at a low work load of 300 kpm/min, an intermediate work load of 600-750 kpm/min and a peak work load of 1092 66 kpm/min supine and 946 ± 146 kpm/min upright (p < 0.05). With peak exercise, supine LVEDV increased significantly, to 135 ± 13 ml (27%), but LVESV did not change. LVEF increased from 76 ± 2% to 84 i 2% (p < 0.05). With upright exercise, LVEDV increased 39% above the resting level, to 116 ± 8 ml (p < 0.02), but remained lower than the supine LVEDVs at intermediate (p < 0.05) and peak work loads. LVESV decreased significantly by 41%, to 19 ± 3 ml, and was significantly smaller than the corresponding supine volume at intermediate and peak exercise (p < 0.05). LVEF increased from 72 ± 4% to 91 ± 2% (p < 0.05), which was significantly higher than peak supine LVEF (p < 0.05). Heart rates at rest and during exercise were higher in the upright position (p < 0.05), but arterial pressures and double products did not differ significantly. Measurements of LV volumes at rest and during exercise in both the supine and upright positions by dynamic radionuclide scintigraphy suggest that stroke volume during exercise is maintained by a combination of the Frank-Starling mechanism and an enhanced contractile state.
منابع مشابه
IOP variations in the sitting and supine positions.
PURPOSE The aim of this study was to assess the influence of the position (upright vs. supine) in the intraocular pressure (IOP) measured with a non-contact portable tonometer. METHODS Fifty university students with a mean age of 22.3±4.2 years (mean±SD) were recruited to participate in this study. IOP was measured with the non-contact tonometer Keeler, Pulsair EasyEye. Measurements in uprigh...
متن کاملLeft ventricular performance in normal subjects: a comparison of the responses to exercise in the upright and supine positions.
Left ventricular (LV) performance at rest and during multilevel exercise in the supine and upright positions was studied in seven normal subjects with equilibrium radionuclide ventriculography. The mean left ventricular end-diastolic volume (LVEDV) during supine rest was 107 4 10 ml (± SEM) and 85 ± 6 ml (p < 0.02) in the upright position; the mean resting left ventricular end-systolic volumes ...
متن کاملAlveolar oxygen uptake and femoral artery blood flow dynamics in upright and supine leg exercise in humans.
We tested the hypothesis that the slower increase in alveolar oxygen uptake (VO2) at the onset of supine, compared with upright, exercise would be accompanied by a slower rate of increase in leg blood flow (LBF). Seven healthy subjects performed transitions from rest to 40-W knee extension exercise in the upright and supine positions. LBF was measured continuously with pulsed and echo Doppler m...
متن کاملEsophageal Motility in the Supine and Upright Positions for Liquid and Solid Swallows Through High-resolution Manometry
BACKGROUND/AIMS Most recent studies using high-resolution manometry were based on supine liquid swallows. This study was to evaluate the differences in esophageal motility for liquid and solid swallows in the upright and supine positions, and to determine the percentages of motility abnormalities in different states. METHODS Twenty-four asymptomatic volunteers and 26 patients with gastroesoph...
متن کاملDoppler echocardiographic measurement of flow velocity in the ascending aorta during supine and upright exercise.
Doppler echocardiography was used to measure stroke volume, peak flow velocity, and acceleration of flow in the ascending aorta in 10 healthy young volunteers during unlimited supine bicycle exercise and upright treadmill exercise. High quality studies were obtained in all subjects through the suprasternal notch acoustic window; there was no appreciable degradation in Doppler signal caused by i...
متن کامل