Reliability of cardiorespiratory measurements during wheelchair ergometry.

نویسندگان

  • R E Keyser
  • M M Rodgers
  • E R Rasch
چکیده

The purpose of this research was to evaluate the stability of measures of heart rate (HR) and oxygen uptake (VO2) during repeated 30-minute bouts of constant work-rate wheelchair ergometry. Ten able-bodied subjects (seven male; three female) completed three sequential, single-stage wheelchair ergometer propulsion tests, to exhaustion, at least 48 hours apart, to determine the reliability of measurements of HR and VO2. Power output was determined as the resistance required to elicit 75% of the peak V02 attained during a peak graded exercise wheelchair ergometer test, at a propulsion velocity of three miles per hour and a flywheel roll distance of 6.32 meters. The HR and VO2 measurements were averaged over the last 30 seconds of the first (T1) and second (T2) thirds of the tests and at volitional exhaustion (T3). Significant differences were not observed at any of the data points except for HR at exhaustion. The HR at exhaustion was lower for the third test than for the second test. Intraclass correlation coefficients for HR (R=0.92, 0.95, and 0.86) and VO2 (R=0.95, 0.96, and 0.97) were high across the three tests, at all of the data points, respectively. Coefficients of variation were generally low. The results of this study indicated that, with the exception of HR during exercise sustained longer than approximately 30 minutes, VO2 and HR measurements can be made with high reliability during sustained wheelchair ergometer propulsion.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Reliability of biomechanical variables during wheelchair ergometry testing.

Wheelchair ergometer testing is used to characterize wheelchair propulsion mechanics. The reliability of kinematic and kinetic measures has not been investigated for wheelchair ergometer testing. In this study, test-retest reliability of biomechanical measurements on a wheelchair ergometer was determined during a submaximal endurance test. Ten nondisabled subjects (seven male, three female), in...

متن کامل

Rating of Perceived Exertion as an Indicator of Exercise Intensity in Paraplegics

Background: Energy expenditure is of paramount importance in the assessment of usefulness of wheelchair for paraplegics. Despite widespread recognition of problems associated with currently available mobility systems for persons with spinal cord injuries, development of more efficient systems has been slow.  Lack of a suitable and simple technique for the assessment of energy expenditure in par...

متن کامل

Effects of Upper Limb Exercises on Physical Capacity and Heart Function in Quadriplegics

Objectives: Wheelchairs are the prime mobility aid of persons with spinal cord injuries. Manual wheelchair propulsion puts a lot of demand on the cardiopulmonary as well as the skeletal system. The main purpose of the study was to compare the effects of both arm ergometry training and progressive resistance exercise training of upper limbs on resting heart rate and distance covered during wheel...

متن کامل

Power output for wheelchair driving on a treadmill compared with arm crank ergometry.

OBJECTIVES The limiting factors with regard to power output available for wheelchair ambulation have not been identified. The aim of the present study was to correlate power output during wheelchair driving with (i) power output and oxygen uptake during arm crank ergometry and (ii) arm muscle strength. METHODS Eleven disabled men were examined for maximal power output (POmax) during wheelchai...

متن کامل

Effects of Upper Limb Exercises on Physical Capacity and Heart Function in Quadriplegics

Introduction: Wheelchairs are the prime mobility aid of persons with spinal cord injuries. Manual wheelchair propulsion puts a lot of demand on the cardiopulmonary as well as the skeletal system. The main purpose of the study was to compare the effects of both arm ergometry training and progressive resistance exercise training of upper limbs on resting heart rate and distance covered during whe...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of rehabilitation research and development

دوره 38 4  شماره 

صفحات  -

تاریخ انتشار 2001