The development of scotopic sensitivity.

نویسندگان

  • A B Fulton
  • R M Hansen
چکیده

UNLABELLED PURPOSE. Test the hypothesis that the developmental increases in rod photoreceptor sensitivity and rod-mediated visual sensitivity at 10 degrees, 20 degrees , and 30 degrees eccentric are concurrent. It is known that maturation of the parafoveal (10 degrees eccentric) rod outer segments and visual sensitivity is delayed compared to that at 30 degrees eccentric. METHODS Rod isolated electroretinographic (ERG) responses to full-field stimuli were obtained from dark-adapted subjects (n = 71), ranging in age from early infancy through middle age. Rod photoreceptor sensitivity was calculated by fitting a model of the activation of phototransduction to the a-wave response. Rod driven b-wave sensitivity was calculated from stimulus-response functions. A logistic growth model was used to summarize the developmental increases in sensitivity of the rod photoreceptors and the b-wave. Previously reported dark-adapted, rod-mediated visual sensitivities at 10 degrees , 20 degrees, and 30 degrees eccentric, obtained using preferential looking procedures, were reanalyzed using the logistic growth model. RESULTS The logistic growth model accounted for 57% to 85% of the variance of each sensitivity parameter with age in normal subjects. The shape of the growth curve and the age at which sensitivity reaches 50% of the adult value is similar (10.0-13.5 weeks) for the rods, the b-wave, and peripheral visual sensitivity, but is significantly older, 19.5 weeks, for rod-mediated parafoveal visual sensitivity. CONCLUSIONS Rod photoreceptor sensitivity and peripheral, rod-mediated visual sensitivity develop concurrently. A parsimonious explanation is that rod photoreceptor sensitivity determines dark-adapted, rod-mediated visual sensitivity during development.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Human scotopic sensitivity is regulated postreceptorally by changing the speed of the scotopic response.

Sensitivity regulation enables the visual system to function effectively from the absorption of a few photons at the lowest visual threshold to the absorption of enough photons to bleach nearly all the light-sensitive photopigment in the eye. Here, we investigate sensitivity regulation in the rod (or scotopic) range from -3.8 to -0.8 log(10) scotopic trolands. Over most of this range, the rate ...

متن کامل

Night vision in the elderly: consequences for seeing through a "blue filtering" intraocular lens.

Relative scotopic spectral sensitivity depends only on the rhodopsin photopigment and ocular media absorption spectra. Rhodopsin is well characterised so the relative scotopic spectral sensitivity function can be calculated for intraocular lenses (IOLs) of known spectral density. In a recent perspective, Mainster and Sparrow concluded that an IOL with short wave absorbing chromophores would pro...

متن کامل

Effects of Chronic and Acute Intraocular Pressure Elevation on Scotopic and Photopic Contrast Sensitivity in Mice

PURPOSE To compare the impact of intraocular pressure (IOP) elevation on scotopic and photopic contrast sensitivity in mice. METHODS We chronically elevated the IOP of wild-type mice via injection of polystyrene beads or acutely via injection of highly cohesive sodium hyaluronate. Some eyes with chronically elevated IOP were treated with either topical brimonidine tartrate 0.1% or brinzolamid...

متن کامل

Dissociations in Coherence Sensitivity Reveal Atypical Development of Cortical Visual Processing in Congenital Achromatopsia.

PURPOSE While basic visual functions have been described in subjects with congenital achromatopsia (ACHM), little is known about their mid- or high-level cortical visual processing. We compared midlevel cortical visual processing in ACHM subjects (n = 11) and controls (n = 20). METHODS Abilities to detect global form, global motion, and biological motion embedded in noise were tested across a...

متن کامل

Scotopic Microperimetry in the Early Diagnosis of Age-Related Macular Degeneration: Preliminary Study

BACKGROUND Recent clinical studies have shown that, in some degenerative retinal diseases, like age-related macular degeneration (AMD), the sensitivity of the rods decreases more rapidly than the sensitivity of the cones. The aim of this study was to evaluate if there is a correlation between the presence of hard drusen at the macular level and the rod damage responsible for the reduction in sc...

متن کامل

Photopic and scotopic flicker sensitivity of a rod monochromat.

The sensitivity to sine-wave flicker of a rod monochromat was compared with that of a normal subject at photopic and scotopic levels of luminance. The sensitivity of the rod monochromat in the low-frequency region (below 3 Hz at scotopic levels and below 12 to 14 Hz at photopic levels) was found to be superior to that of the control. This superiority was most pronounced at photopic levels, wher...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 41 6  شماره 

صفحات  -

تاریخ انتشار 2000