Color and Luminance Management for High-Resolution Liquid-Crystal Displays
نویسندگان
چکیده
A new method of color management is described which takes advantage of the high pixel density achievable with TFTLCDs. In this method, a calibration 10-bit look-up-table can be loaded into the monitor and implemented as a 2x2 spatial dither block to provide a 10-bit color palette for 8-bit color drive. Other subpixel dithering techniques are also described for monochrome and color high-resolution TFTLCDs. These techniques can create a very large palette, and combined with a 10-bit digital data source to achieve precise luminance and color calibration.
منابع مشابه
Self-calibrating wide color gamut high dynamic range display
High Dynamic Range displays offer higher brightness, higher contrast, better color reproduction and lower power consumption compared to conventional displays available today. In addition to these benefits, it is possible to leverage the unique design of HDR displays to overcome many of the calibration and lifetime degradation problems of liquid crystal displays, especially those using light emi...
متن کاملCharacterization of crosstalk in high-resolution active-matrix liquid crystal displays for medical imaging
In active-matrix liquid crystal displays with large pixel array and large number of graylevels, the luminance of a pixel depends on the luminance of the rest of the image. This artifact known as crosstalk is caused by parasitic phenomena in the active-matrix array. When interpreting high information content medical images with subtle features and structured background, crosstalk can a ect image...
متن کاملTFT-LCD Driver IC Design
With the rapid evolution of liquid crystal display (LCD) television (TV), there is a large demand for developing high resolution, high color depth driver integrated circuits (ICs) [13]. The panel of an LCD-TV is larger, and has higher definition, than that of a computer monitor. As a result, its color quality requires more accuracy. For example, computer monitors have 2 (262,144) or 2 (16,777,2...
متن کاملAuthor ' s personal copy Psychophysical contrast calibration q
Electronic displays and computer systems offer numerous advantages for clinical vision testing. Laboratory and clinical measurements of various functions and in particular of (letter) contrast sensitivity require accurately calibrated display contrast. In the laboratory this is achieved using expensive light meters. We developed and evaluated a novel method that uses only psychophysical respons...
متن کاملGenerating high gray-level resolution monochrome displays with conventional computer graphics cards and color monitors.
Display systems based on conventional computer graphics cards are capable of generating images with about 8-bit luminance resolution. However, most vision experiments require more than 12 bits of luminance resolution. Pelli and Zhang [Spatial Vis. 10 (1997) 443] described a video attenuator for generating high luminance resolution displays on a monochrome monitor, or for driving just the green ...
متن کامل