Ventilation efficacy of video-laryngoscopes equipped with a ventilation feature.

نویسندگان

  • Jun Oto
  • Christopher T Chenelle
  • Zhenbo Su
  • Mary Q Sun
  • Yandong Jiang
  • Robert M Kacmarek
چکیده

INTRODUCTION Achieving effective ventilation is challenging for anesthesia care providers and emergency medical personnel, as difficult mask ventilation and difficult intubation frequently occur. The aim of this study was to determine whether video-laryngoscopes equipped with a ventilation feature can produce effective ventilation. METHODS An intubation mannequin with its trachea connected to a model lung with compliance 50 (normal compliance: C50) and 20 mL/cm H2O (low compliance: C20) was used. Ventilation was established via a ventilation catheter (inner diameter 3.5 mm, 50 cm length) extending to the tip of the video-laryngoscope blade. Three different views of the vocal cords (grade 1, vocal cords fully visualized; grade 2, partial vocal cord visualization; grade 3, only epiglottis visualized) were tested. Ventilation was provided by jet ventilator (Jet). The Jet was operated at 10, 15, and 20 psi (Jet10, Jet15, and Jet20). Effective tidal volume (V(T)) was defined as a V(T) greater than anatomical dead space (150 mL). RESULTS In C50, Jet15 and Jet20 generated effective V(T) in all vocal cord views (for Jet15: grade 1, 663 ± 33 mL; grade 2, 363 ± 25 mL; and grade 3, 198 ± 9 mL; for Jet20: grade 1, 1,005 ± 114 mL; grade 2, 484 ± 38 mL; grade 3, 268 ± 8 mL, respectively). In C20, Jet15 and Jet20 generated effective V(T) in grades 1 and 2 (Jet15: grade 1, 288 ± 8 mL; grade 2, 160 ± 20 mL; grade 3, 81 ± 7 mL; Jet20: grade 1, 421 ± 20 mL; grade 2, 222 ± 16 mL; grade 3, 111 ± 8 mL, respectively). Jet10 achieved effective V(T) in grade 1 and 2 (grade 1, 354 ± 6 mL; grade 2, 223 ± 37 mL, respectively) in C50 and grade 1 (163 ± 12 mL) in C20. CONCLUSIONS Video-laryngoscopes equipped with a ventilation feature provided effective V(T) in simulated clinical scenarios. Further clinical study is required to validate these findings.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Randomized Comparison Simulating Face to Face Endotracheal Intubation of Pentax Airway Scope, C-MAC Video Laryngoscope, Glidescope Video Laryngoscope, and Macintosh Laryngoscope

OBJECTIVES Early airway management is very important for severely ill patients. This study aimed to investigate the efficacy of face to face intubation in four different types of laryngoscopes (Macintosh laryngoscope, Pentax airway scope (AWS), Glidescope video laryngoscope (GVL), and C-MAC video laryngoscope (C-MAC)). METHOD Ninety-five nurses and emergency medical technicians were trained t...

متن کامل

Comparison of the McGrath® Series 5 and GlideScope® Ranger with the Macintosh laryngoscope by paramedics

BACKGROUND Out-of-hospital endotracheal intubation performed by paramedics using the Macintosh blade for direct laryngoscopy is associated with a high incidence of complications. The novel technique of video laryngoscopy has been shown to improve glottic view and intubation success in the operating room. The aim of this study was to compare glottic view, time of intubation and success rate of t...

متن کامل

TotalTrack video intubating laryngeal mask in super-obese patients – series of cases

BACKGROUND Super-obese patients are at increased risk of difficult mask ventilation and difficult intubation. Therefore, devices that allow for simultaneous ventilation/oxygenation during attempts to visualize the entrance to the larynx, increase patient safety. TotalTrack video intubating laryngeal mask is a new device that allows for ventilation during intubation efforts. PATIENTS AND METHO...

متن کامل

Aprospective randomized study comparing respiratory efficacy of percutaneous transtracheal and endotracheal, low-frequency jet ventilation during microlaryngeal surgery

 Abstract Background: Transtracheal jet ventilation is an alternative ventilatory approach in airway surgery. The purpose of this study was to compare respiratory efficacy of percutaneous transtracheal with endotracheal, low frequency jet ventilation during microlaryngeal surgery. Methods: Ninety ASA class I-II patients aged between 16 and 70 years undergoing elective microlaryngeal surgery wer...

متن کامل

Methods of administering superimposed high-frequency jet ventilation and the associated risk for aspiration in a model of tracheal bleeding.

BACKGROUND To determine the suitability of different superimposed high-frequency jet ventilation (SHFJV) application methods during tracheal bleeding. OBJECTIVE To determine the effect of SHFJV on the aspiration of blood during tracheal bleeding. METHODS A test lung was ventilated using SHFJV via a rigid endoscope, a jet laryngoscope and a 4-lumen jet catheter. Packed red blood cells (PRBCs...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Respiratory care

دوره 59 11  شماره 

صفحات  -

تاریخ انتشار 2014