Giant coronary artery aneurysm: imaging findings before and after treatment with a polytetrafluoroethylene-covered stent.

نویسندگان

  • Parham Eshtehardi
  • Stéphane Cook
  • Igal Moarof
  • Hans-Jürgen Triller
  • Stephan Windecker
چکیده

Coronary artery aneurysm (CAA), defined as dilatation of the coronary artery exceeding 50% of the reference vessel diameter, is uncommon and occurs in 5% of coronary angiographic series.1 CAAs are termed giant if their diameter exceeds the reference vessel diameter by 4 times or if they are 8 mm in diameter.2 Atherosclerosis accounts for the vast majority of CAAs in adults, whereas Kawasaki disease is responsible for most cases in children.1,2 Up to one third of CAAs are associated with obstructive coronary artery disease and have been associated with myocardial infarction, arrhythmias, or sudden cardiac death.3 A 63-year-old man with typical chest pain and a positive treadmill exercise test was referred for diagnostic coronary angiography. Six years before this hospitalization, the patient had suffered from a subdural hematoma, undergone surgical ligation of a large aneurysm of the left middle cerebral artery in the presence of 2 smaller aneurysms of the right pericallosal artery and internal carotid artery. Oral anticoagulation was initiated after surgery and has been maintained since then. Cardiovascular risk factors consisted of arterial hypertension, diabetes mellitus, dyslipidemia, obesity, a family history for coronary artery disease, and smoking. Coronary angiography showed a focal stenosis of the mid segment of the left anterior descending artery (LAD), followed by a giant coronary aneurysm measuring 16 22 mm (Figure 1A). To alleviate the significant stenosis of the mid-LAD and exclude the giant CAA, percutaneous coronary intervention was planned. Intravascular ultrasound (IVUS) (Atlantis SR 40MHz, iLab, Boston Scientific Inc, Boston, Mass) images were acquired before percutaneous coronary intervention to estimate vessel size and length of the base of the aneurysm (Figure 1B). After IVUS, the proximal stenosis was treated with a 3.0/20-mm balloon (Maverick 2, Boston Scientific Inc) inflated to 10 bars for 12 seconds. Thereafter, the aneurysm was excluded from the native coronary artery by placement of a 3.5/26-mm polytetrafluoroethylene (PTFE)--covered stent (Graft-

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Delayed endothelialization after polytetrafluoroethylene-covered stent implantation for coronary aneurysm.

A polytetrafluoroethylene (PTFE)-covered stent is specially used to treat coronary perforation complicating percutaneous intervention in order to prevent the aneurysm from rupturing, but until now it has not been known if endothelialization occurs inside this type of stent. A patient with a giant aneurysm of the right coronary artery underwent successful implantation of a PTFE-covered stent. An...

متن کامل

Generation of a giant coronary artery aneurysm from an intra-plaque cavity with a ruptured fibrous cap: an observation over time through coronary angiography.

A 74-year-old man underwent coronary artery bypass graft surgery. Thirteen years later, he presented with complaints of exertional anterior chest oppression again. Computed tomography coronary angiography revealed the significant stenosis at the mid right coronary artery (RCA). In addition, a giant proximal left anterior descending (LAD) coronary artery aneurysm (CAA) was found. We did not obse...

متن کامل

Case Image: Percutaneous approach to giant coronary artery aneurysm: successful implantation of covered stent graft.

A 65-year-old male patient was referred with exertional chest pain. He had a history of left anterior descending artery (LAD) stent and hypertension. The patient was diagnosed as non-ST elevation myocardial infarction (non-STEMI) due to ischemic changes on the electrocardiogram and a high troponin level. Coronary angiography illustrated a subtotal occlusion of the circumflex artery (Cx) and a g...

متن کامل

Late giant coronary aneurysm associated with a fracture of sirolimus eluting stent: a case report.

A 73-year-old female underwent percutaneous coronary intervention (PCI) because of stable angina. An elective PCI for the RCA lesion was first performed with deploying sirolimus eluting stents (SES). Three weeks later, PCI was also provided in the residual LAD lesion. Eight months later, she presented with new angina. CAG revealed an in-stent restenosis in the mid LAD and a large eccentric sacc...

متن کامل

Management of a large coronary artery aneurysm with graft-coated stent during the acute phase of myocardial infarction

Coronary aneurysms in adults are rare clinical entities. Herein, we presented a 54-year-old man who was admitted with an acute extensive anterior myocardial infarction. The emergency coronary angiography revealed an isolated large aneurysm at the proximal segment of the left anterior descending coronary artery. The patient was successfully treated with a graft-coated stent

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation. Cardiovascular interventions

دوره 1 1  شماره 

صفحات  -

تاریخ انتشار 2008