Clinical Evaluation of the Resolute Zotarolimus-Eluting Coronary Stent System in the Treatment of De Novo Lesions in Native Coronary Arteries

نویسندگان

  • Alan C. Yeung
  • Jeffrey J. Popma
چکیده

Methods The R-US trial recruited patients with de novo native coronary lesions suitable for 1or 2-vessel treatment with stents from 2.25 to 4.0 mm in diameter. In the main analysis cohort (2.5to 3.5-mm stents and single-lesion treatment), the primary endpoint was 12-month target lesion failure (TLF) defined as the composite of cardiac death, myocardial infarction (MI), and clinically-driven target lesion revascularization (TLR), compared with data from Endeavor zotarolimus-eluting stent (E-ZES) trials, adjusting for baseline covariates through propensity scores.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Clinical evaluation of the Resolute zotarolimus-eluting coronary stent system in the treatment of de novo lesions in native coronary arteries: the RESOLUTE US clinical trial.

OBJECTIVES The RESOLUTE US (R-US) trial is a prospective, observational study designed to evaluate the clinical effectiveness of the Resolute zotarolimus-eluting stent (R-ZES) in a U.S. population. BACKGROUND The R-ZES releases zotarolimus over a 6-month period in order to achieve optimal clinical effectiveness and safety. METHODS The R-US trial recruited patients with de novo native corona...

متن کامل

Impact of polymer formulations on neointimal proliferation after zotarolimus-eluting stent with different polymers: insights from the RESOLUTE trial.

BACKGROUND Polymer formulation may affect the efficacy of drug-eluting stents. Resolute, Endeavor, and ZoMaxx are zotarolimus-eluting stents with different stent platforms and different polymer coatings and have been tested in clinical trials. The aim of this analysis was to compare the efficacy of zotarolimus-eluting stents with different polymers. METHODS AND RESULTS Data were obtained from...

متن کامل

Impact of Polymer Formulations on Neointimal Proliferation After Zotarolimus-Eluting Stent With Different Polymers

Background—Polymer formulation may affect the efficacy of drug-eluting stents. Resolute, Endeavor, and ZoMaxx are zotarolimus-eluting stents with different stent platforms and different polymer coatings and have been tested in clinical trials. The aim of this analysis was to compare the efficacy of zotarolimus-eluting stents with different polymers. Methods and Results—Data were obtained from t...

متن کامل

Comparison of resolute zotarolimus-eluting stents and sirolimus-eluting stents in patients with de novo long coronary artery lesions: a randomized LONG-DES IV trial.

BACKGROUND Procedural and clinical outcomes still remain unfavorable for patients with long coronary lesions who undergo stent-based coronary interventions. Therefore, we compared the relative efficacy and safety of resolute zotarolimus-eluting stents (R-ZES) and sirolimus-eluting stents (SES) for patients with de novo long coronary lesions. METHODS AND RESULTS This randomized, multicenter, p...

متن کامل

Resolute zotarolimus eluting stent for treatment of long coronary lesions.

Historically the treatment of long coronary lesions required overlapping stents, which has been associated with higher incidence of cardiovascular events. The current availability of long drug eluting stentsizes has enabled treatment of such lesions with one, or at least fewer stents e reducing cost and areas of stent overlap. However, longer lesion and stent length continues to be associated w...