Selection of spiral capillary tube for refrigeration appliances and the effect of changes in the parameters such as capillary tube dimensions i.e. capillary tube diameter, coil pitch, capillary tube length and inlet conditions of refrigerant to the capillary tube i.e. degree of subcooling, inlet pressure on the mass flow rate of the refrigerant, also investigation about the coiling effect of spiral capillary tube on mass flow rate of refrigerant for same cooling load is reviewed in this paper. The characteristics coiling parameter for a spiral capillary tube is the coil pitch; hence, the effect of the coil pitch on the mass flow rate of refrigerant for several spiral capillary tube test sections plays vital role in investigation of the performance. The review is focused on the influence of tube diameter, tube length, coil pitch, and inlet condition on mass flow rate of refrigerant through spiral capillary tube, and also on investigation about the Coefficient of Performance (COP) of the system due to coiling effect of capillary tube. The use of spiral capillary tube reduces the space for the refrigeration system which is the need for more compact refrigeration system in the current trend. As the spiral capillary tube can be efficient in refrigeration appliances, it can also be employed in the air conditioning appliances.
منابع مشابه
Selection of Capillary Tube for Refrigeration System
Proper selection of capillary tube it is essential to study the effect of capillary tube geometry on the performance of refrigeration systems. The literature review is focused on the influence of geometrical parameters like tube length, diameter, coil pitch, number of twist and twisted angle on pressure drop and coefficient of performance (COP) of the system. These parameters can be optimized u...
متن کاملExperimental Analysis of Capillary Tubes for CFC-12 and HFC-134a
This work presents experimental data for capillary tubes of the type commonly used as expansion devices in domestic appliances, employing CFC-12 and HFC-134a as working fluids. Capillary tubes of 0. 7, 0.8 and 1.0 millimeter internal diameter with lengths of 3 and 2 meters were tested. Condensing pressures of 18, 14, 11 and 9 bar, and subcooling ranging from 14 to 2 oc were chosen as the operat...
متن کاملExperimental Study on the Performance of Twisted Capillary Tube
A novel capillary tube has been tested and evaluated experimentally in the refrigeration cycle of window type air conditioner. Three twisted capillary tubes have been demonstrated and evaluated to show the performance of these tubes and its ability in the depressurization process seeking for short capillary tube. The effect of twist angle and the number of twisted points on the refrigeration cy...
متن کاملRating Charts of R-22 Alternatives Flow through Adiabatic Capillary Tubes
Drop-in of R-22 alternatives in refrigeration and air conditioning systems requires a redesign of system components to improve system performance and reliability with the alternative refrigerants. The present paper aims at design adiabatic capillary tubes for R-22 alternatives such as R-417A, R-422D and R-438A. A theoretical model has been developed and validated with the available experimental...
متن کاملImpact of Refrigerant Charge over the Performance Characteristics of a Simple Vapour Compression Refrigeration System
Experimental investigation was done to find the role of capillary tube length and amount of refrigerant charge on the overall heat transfer coefficient in condenser and evaporator and actual COP of a simple vapour compression refrigeration system. It was concluded that increasing of the refrigerant charge in the system largely enhances the overall heat transfer coefficient in the evaporator by ...