Human hydrometry: comparison of multifrequency bioelectrical impedance with H2O and bromine dilution

نویسندگان

  • KENNETH J. ELLIS
  • WILLIAM W. WONG
چکیده

Ellis, Kenneth J., and William W. Wong. Human hydrometry: comparison of multifrequency bioelectrical impedance with H2O and bromine dilution. J. Appl. Physiol. 85(3): 1056–1062, 1998.—The traditional method of assessing total body water (TBW), extracellular water (ECW), and intracellular water (ICW) has been the use of isotopes, on the basis of the dilution principle. Although the development of bioelectrical impedance techniques has eliminated many of the measurement constraints associated with the dilution methods, the degree of interchangeability between the two methods remains uncertain. We used multifrequency bioelectrical impedance spectroscopy (BIS), H2O dilution, and bromine dilution to assess TBW, ECW, and ICW in 469 healthy subjects (248 males, 221 females) aged 3–29 yr. We found that the TBW, ECW, and ICW estimates for the BIS and dilution methods were significantly correlated (r2 5 0.80–0.96, P , 0.0001, SE of the estimate 5 2.3–2.7 liters). On the basis of population, the constants used in the BIS analysis could be adjusted so that the mean differences with the dilution methods would become zero. The SD values for the mean differences between the dilution and BIS methods, however, remained significant for both males and females: TBW (62.1– 2.8 liters), ECW (61.4–1.6 liters), and ICW (2.0–3.1 liters). To improve the accuracy of the BIS measurement for an individual within the age range we have examined, further refinement of the constants used in the BIS analysis is needed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Human hydrometry: comparison of multifrequency bioelectrical impedance with 2H2O and bromine dilution.

The traditional method of assessing total body water (TBW), extracellular water (ECW), and intracellular water (ICW) has been the use of isotopes, on the basis of the dilution principle. Although the development of bioelectrical impedance techniques has eliminated many of the measurement constraints associated with the dilution methods, the degree of interchangeability between the two methods r...

متن کامل

Comparative measurements of total body water in healthy volunteers by online breath deuterium measurement and other near-subject methods1–3

Background: We developed a new near-subject approach, using flowing afterglow–mass spectrometry (FA-MS) and deuterium dilution, which enables the immediate measurement of total body water (TBW) from single exhalations. Objectives: The objectives were to show the efficacy of the new FA-MS method in measuring TBW in healthy subjects and to compare these measurements with values derived from multi...

متن کامل

Comparison of single- or multifrequency bioelectrical impedance analysis and spectroscopy for assessment of appendicular skeletal muscle in the elderly.

Bioelectrical impedance analysis (BIA) is used to assess skeletal muscle mass, although its application in the elderly has not been fully established. Several BIA modalities are available: single-frequency BIA (SFBIA), multifrequency BIA (MFBIA), and bioelectrical impedance spectroscopy (BIS). The aim of this study was to examine the difference between SFBIA, MFBIA, and BIS for assessment of ap...

متن کامل

Comparative measurements of total body water in healthy volunteers by online breath deuterium measurement and other near-subject methods.

BACKGROUND We developed a new near-subject approach, using flowing afterglow-mass spectrometry (FA-MS) and deuterium dilution, which enables the immediate measurement of total body water (TBW) from single exhalations. OBJECTIVES The objectives were to show the efficacy of the new FA-MS method in measuring TBW in healthy subjects and to compare these measurements with values derived from multi...

متن کامل

Single- and multifrequency models for bioelectrical impedance analysis of body water compartments.

The 1994 National Institutes of Health Technology Conference on bioelectrical impedance analysis (BIA) did not support the use of BIA under conditions that alter the normal relationship between the extracellular (ECW) and intracellular water (ICW) compartments. To extend applications of BIA to these populations, we investigated the accuracy and precision of seven previously published BIA models...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1998