Validation of the calibration of a OH LIF instrument

نویسندگان

  • W. J. Bloss
  • J. D. Lee
  • C. Bloss
  • K. Wirtz
  • M. Martin-Reviejo
  • M. Siese
  • D. E. Heard
  • M. J. Pilling
چکیده

Validation of the calibration of a laser-induced fluorescence instrument for the measurement of OH radicals in the atmosphere W. J. Bloss, J. D. Lee, C. Bloss, K. Wirtz, M. Martin-Reviejo, M. Siese, D. E. Heard, and M. J. Pilling Department of Chemistry, University of Leeds, Woodhouse Lane, Leeds, LS2 9JT, UK Fundación CEAM, EUPHORE Laboratories, C/Charles Darwin 14, Parque Technológico, 46980 Paterna, Valencia, Spain Institut für Chemie und Dynamik der Geosphäre, Institut II: Troposphäre, Forschungszentrum Jülich, D-52425 Jülich, Germany Received: 28 October 2003 – Accepted: 21 November 2003 – Published: 28 November 2003 Correspondence to: W. Bloss ([email protected])

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Validation of the calibration of a laser-induced fluorescence instrument for the measurement of OH radicals in the atmosphere

An assessment of the accuracy of OH concentrations measured in a smog chamber by a calibrated laserinduced fluorescence (LIF) instrument has been made, in the course of 9 experiments performed to study the photooxidation of benzene, toluene, 1,3,5-trimethylbenzene, paraxylene, ortho-cresol and ethene at the European Photoreactor facility (EUPHORE). The LIF system was calibrated via the water ph...

متن کامل

A Validation Study on Radiation properties of a Novel LiF: Mg, Ti Known as IAP-100

Introduction: LiF dosimeter has the most application in medicine. This study aimed to evaluate some dosimetric properties of a novel LiF: Mg, Ti. Materials and Methods: An ELEKTA Precise linear accelerator was used to calibrate dosimeters at 6 MV. In this survey, responses of dosimeters were evaluated up to 1000 cGy. Background effect was investigated in two different dosimeter states includin...

متن کامل

Calibration of laser induced fluorescence of the OH radical by cavity ringdown spectroscopy in premixed atmospheric pressure flames

Cavity ringdown spectroscopy (CRDS) of the hydroxyl radical (OH) has been explored in a laminar methane-air flame at atmospheric pressure over a range of equivalence ratio. Laser induced fluorescence of OH calibrated by CRDS in a lean flame compares well to PREMIX calculations using GRI-Mech 3.0. CRDS is a highly sensitive path-integrated diagnostic technique that can yield absolute absorber nu...

متن کامل

Development of near infrared reflectance spectroscopy (NIRS) calibration model for estimation of oil content in a worldwide safflower germplasm collection

The development of NIRS calibration model as a rapid, precise, robust, and cost-effective method to estimate oil content in ground seeds of worldwide safflower germplasm collection grown under different agro-climatic conditions was the key objective of this research project. The oil content was measured by accelerated solvent extraction method in a total of 328 samples collected across 2004 (16...

متن کامل

EXPERIMENTAL EVALUATION OF OBSERVATION BASED METHODS FOR ASSESSING THE SENSITIVITY OF OZONE TO VOC AND NOx

......................................................................................................................................... 1 1. Background................................................................................................................................ 2 2. Project Summary..................................................................................................

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2003