Mandible distraction using internal device: mathematical analysis of the results.

نویسندگان

  • Renato da Silva Freitas
  • Nivaldo Alonso
  • Luciano Busato
  • Ubiratã D'oro
  • Marcus Castro Ferreira
چکیده

For many years, surgeons have sought a method to treat severe facial deformities without using bone grafts and extensive surgery. Distraction osteogenesis offers this promise. The technique used in mandibular hypoplasia follows the basic principles proposed by Ilizarov which states that the device must be elongated 1 mm per day to create optimal bone production. Despite the widespread implementation of this recommendation to include the 1-mm/day separation, doubt still exists as to whether this is the optimal treatment regimen. Intraoral devices with percutaneous activator pins were used in 16 patients with hypoplastic mandibles. The results of distraction were documented by panorex and cephalogram of the mandible. The length of the ramus as well as multiple mandible dimensions and facial angles were measured. The panorex and cephalogram of the mandible were effective in demonstrating the significant increase in length of the mandible and ramus, as well as the entire mandible, but there was no correlation between the stretching obtained by the distraction device and that measured by the radiographic studies. The S-N-B angle was the only facial angle in which there is a statistically significant increase measured and this appeared to be related to a mandible rotation. It is concluded that the mandible distraction (using an intraoral device and an external activator pin) was effective in increasing the ramus length and both the panorex and the cephalogram were effective in demonstrating this morphologic change. There was no correlation between the clinical result and the radiographic studies demonstrating that the clinical judgment still has a significant role in controlling mandible distraction.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The effect of latency on bone lengthening force and bone mineralization: an investigation using strain gauge mounted on internal distractor device

BACKGROUND The purpose of this study was to investigate the effect of latency on the development of bone lengthening force and bone mineralization during mandible distraction osteogenesis. METHODS Distraction tensions were investigated at different latency period in 36 rabbits using internal unilateral distractor. Strain gauges were prepared and attached to the distractor to directly assess t...

متن کامل

Successful Reconstruction of Nerve Defects Using Distraction Neurogenesis with a New Experimental Device

Introduction: Repair of peripheral nerve injuries is an intensive area of challenge and research in modern reconstructive microsurgery. Intensive research is being carried out to develop effective alternatives to the standard nerve autografting, avoiding its drawbacks. The aim of the study was to evaluate the effectiveness of a newly designed mechanical device for the reconstruction of the...

متن کامل

External versus Internal Distraction Devices in Treatment of Obstructive Sleep Apnea in Craniofacial Anomalies

BACKGROUND Obstructive sleep apnea is often associated with congenital craniofacial malformations due to hypoplastic mandible and decreased pharyngeal airway. In this study, we will compare external and internal distraction devices for mandibular lengthening in terms of effectiveness, results, patient comfort, and complications. METHODS Thirty-seven patients were treated by bilateral mandibul...

متن کامل

Mandibular distraction force: laboratory data and clinical correlation.

PURPOSE In vitro data were collected to measure torque-force values of an internal distraction device. The measurements were correlated with in vivo torque readings in an attempt to better understand the force required to distract the osteogenic bone callus of the human mandible during distraction osteogenesis. METHODS AND MATERIALS Five internal craniofacial distraction devices were mounted ...

متن کامل

Osteosynthesis and simultaneous irregular trifocal distraction osteogenesis for segmental mandibular defect after tumor ablative surgery: a case report.

OBJECTIVE This paper describes a case of secondary mandibular bone reconstruction performed to place dental implants. Osteosynthesis and simultaneous irregular trifocal distraction osteogenesis were documented. PATIENT The patient was a 51-year-old man with recurrent ameloblastoma of the mandible. Segmental mandibulectomy for tumor ablation and immediate mandibular reconstruction were perform...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of craniofacial surgery

دوره 18 1  شماره 

صفحات  -

تاریخ انتشار 2007