The effect of needle-insertion depth on the irrigant flow in the root canal: evaluation using an unsteady computational fluid dynamics model.

نویسندگان

  • Christos Boutsioukis
  • Theodor Lambrianidis
  • Bram Verhaagen
  • Michel Versluis
  • Eleftherios Kastrinakis
  • Paul R Wesselink
  • Lucas W M van der Sluis
چکیده

INTRODUCTION The aim of this study was to evaluate the effect of needle-insertion depth on the irrigant flow inside a prepared root canal during final irrigation with a syringe and two different needle types using a Computational Fluid Dynamics (CFD) model. METHODS A validated CFD model was used to simulate irrigant flow from either a side-vented or an open-ended flat 30-G needle positioned inside a prepared root canal (45 .06) at 1, 2, 3, 4, or 5 mm short of the working length (WL). Velocity, pressure, and shear stress in the root canal were evaluated. RESULTS The flow pattern in the apical part of the root canal was similar among different needle positions. Major differences were observed between the two needle types. The side-vented needle achieved irrigant replacement to the WL only at the 1-mm position, whereas the open-ended flat needle was able to achieve complete replacement even when positioned at 2 mm short of the WL. The maximum shear stress decreased as needles moved away from the WL. The flat needle led to higher mean pressure at the apical foramen. Both needles showed a similar gradual decrease in apical pressure as the distance from the WL increased. CONCLUSIONS Needle-insertion depth was found to affect the extent of irrigant replacement, the shear stress on the canal wall, and the pressure at the apical foramen for both needle types.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Irrigation of human prepared root canal – ex vivo based computational fluid dynamics analysis

AIM To analyze the influence of the needle type, insertion depth, and irrigant flow rate on irrigant flow pattern, flow velocity, and apical pressure by ex-vivo based endodontic irrigation computational fluid dynamics (CFD) analysis. METHODS Human upper canine root canal was prepared using rotary files. Contrast fluid was introduced in the root canal and scanned by computed tomography (CT) pr...

متن کامل

Evaluation of irrigant flow in the root canal using different needle types by an unsteady computational fluid dynamics model.

INTRODUCTION The aim of this study was to evaluate the effect of needle tip design on the irrigant flow inside a prepared root canal during final irrigation with a syringe using a validated Computational Fluid Dynamics (CFD) model. METHODS A CFD model was created to simulate the irrigant flow inside a prepared root canal. Six different types of 30-G needles, three open-ended needles and three...

متن کامل

Irrigant flow in the root canal: experimental validation of an unsteady Computational Fluid Dynamics model using high-speed imaging.

AIM To compare the results of a Computational Fluid Dynamics (CFD) simulation of the irrigant flow within a prepared root canal, during final irrigation with a syringe and a needle, with experimental high-speed visualizations and theoretical calculations of an identical geometry and to evaluate the effect of off-centre positioning of the needle inside the root canal. METHODOLOGY A CFD model w...

متن کامل

The effect of different needle-insertion depths on the accuracy of the Root ZX II and Root ZX mini apex locators in the presence of various irrigants

BACKGROUND AND AIM: The aim of the present study was to evaluate the effect of different needle-insertion depths on the accuracy of the Root ZX II and Root ZX mini apex locators in the presence of various irrigants. METHODS: Ninety extracted single-canal human teeth were used in nine experimental groups. The coronal one-third of the canals was preflared, and the length to the major foramen was ...

متن کامل

Effect of needle insertion depth and apical diameter on irrigant extrusion in simulated immature permanent teeth.

The aim of this study was to compare the amount of irrigant extrusion in simulated immature permanent teeth when the apical diameter and needle insertion depth were varied. Thirty single-rooted maxillary incisors with straight root canals were selected. The root length was standardized to a length of 9 mm. The teeth were divided into two experimental groups according to the degree of apical enl...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of endodontics

دوره 36 10  شماره 

صفحات  -

تاریخ انتشار 2010