The impact of proximal cell rewiring compared with distal cell rewiring with single-stent deployment and subsequent kissing balloon inflation in the inadequate jailing of a Kaname stent on the side branch ostium.

نویسنده

  • Fumiaki Nakao
چکیده

BACKGROUND To identify differences between proximal and distal cell rewiring with subsequent kissing balloon inflation (KBI) in the presence of a link connected to a carina on the jailed side branch ostium (SBO). METHODS Kaname stents were deployed in bifurcation models (n = 12) with subsequent KBI and were confirmed by optical coherence tomography. The jailing configuration and cell rewiring were completely controlled and classified as follows: FC-Dist, free carina (no links connected to a carina) and distal cell rewiring; CC-Prox, connected to a carina (the presence of a link connected to a central carina) and proximal cell rewiring; CC-Dist, connected to a carina and distal cell rewiring; and FarDist, far-distal cell rewiring. RESULTS The number of frames with malapposed struts (MS) in the SBO was significantly smaller in the CC-Prox group than in the CC-Dist group (26.7 ± 1.5 and 39.7 ± 0.6, respectively, p < 0.05). The number of frames with MS continuously present from the distal end to the proximal side of the SBO was significantly smaller in the CC-Prox group than in the CC-Dist group (17.0 ± 2.0 and 36.7 ± 5.8, respectively, p < 0.05). The ratio of the maximal opened stent cell area to the SBO area was significantly larger in the CC-Prox group than in the CC-Dist group (64.2 ± 1.2% and 38.8 ± 5.6%, respectively, p < 0.05). CONCLUSIONS This study showed that in cases with a link connected to a carina, fewer malapposed struts may be present in proximal cell rewiring with subsequent KBI than in distal cell rewiring.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Instant stent-accentuated three-dimensional optical coherence tomography of a true bifurcation lesion treated with culotte stenting

A 65-year-old woman was performed percutaneous coronary intervention for a bifurcation lesion of the left anterior descending artery (LAD) and the first diagonal branch (Dg). After pre-dilatation, the proximal LAD-Dg was stented with the platinum-chromium elevolimus-eluting stent (PtCrEES). After rewiring to LAD, the instant stent-accentuated 3-dimensional optical coherence tomography (iSA3D-OC...

متن کامل

New Stenting Technique to Achieve Favorable Jailing Configuration on Side Branch Ostium: Bent Stent Technique

According to data from stent-enhanced three-dimensional optical coherence tomography, incomplete stent apposition after side branch dilation in coronary bifurcation stenting can be reduced by the free carina type (no links bridged from a carina) and by distal cell rewiring. This is the first report to describe a bent stent technique that was devised to achieve the free carina type (no links bri...

متن کامل

[Six-month intravascular ultrasound follow-up of coronary bifurcation lesions treated with rapamycin-eluting stents: technical considerations].

INTRODUCTION AND OBJECTIVES In vitro studies show that stents deform when dilated laterally to access a side branch. This phenomenon may be avoided by use of a kissing balloon at the end of the procedure. However, to date, no in vivo data are available. Our objectives were to investigate the main vessel stent using intravascular ultrasound (IVUS) at six-month follow-up in 55 patients with bifur...

متن کامل

A Novel Push-Fold Method for Removing Side Branch-Jailed Stent Struts Under 3D Optical Coherence Tomography Guidance.

A 70-year-old woman with stenosis at the bifurcation of the left anterior descending artery (LAD) and diagonal branch (Dx) underwent implantation of a Xience Alpine stent (2.5 23 mm; Abbott Vascular, Abbott Park, Illinois) in the LAD under 3-dimensional (3D) optical coherence tomography (OCT) (St. Jude Medical, St. Paul, Minnesota) guidance. 3D-OCT image reconstruction using Intage Realia softw...

متن کامل

Optimal Stent Expansion by Stent Balloon Multiple Inflation at Nominal Pressure in Resistant Lesions: A New Technique

Introduction: This study aimed to evaluate the effects of four-time inflation of the stent balloon at nominal pressure on optimal stent expansion in resistant lesions. Materials and Methods: This interventional study was conducted on 39 patients with coronary artery lesions, in whom Zotarolimus-eluting stents (N=20), Paclitaxel-eluting stents (N=11) and other stents (N=8) were deployed four tim...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Cardiology journal

دوره   شماره 

صفحات  -

تاریخ انتشار 2017