Comparison of ventilator-integrated end-tidal CO2 and transcutaneous CO2 monitoring in home-ventilated neuromuscular patients.

نویسندگان

  • David Orlikowski
  • Helene Prigent
  • Xavier Ambrosi
  • Isabelle Vaugier
  • Sandra Pottier
  • Djillali Annane
  • Frederic Lofaso
  • Adam Ogna
چکیده

BACKGROUND Non-invasive transcutaneous capnometry (TcCO2) is used to assess the home ventilation's efficiency. Recently, end-tidal CO2 (ETCO2) sensors have been integrated in life-support home ventilators. The purpose of this study was to compare the ventilator-integrated ETCO2 with TcCO2, in home-ventilated neuromuscular disease patients. METHODS ETCO2 and TcCO2 were simultaneously measured during one night in 28 patients. Daytime blood gases were drawn on the following morning to measure arterial PCO2 (PaCO2). RESULTS Compared to PaCO2 values, both ETCO2 and TcCO2 showed a small bias (-0.1 mmHg and 0.6 mmHg, respectively) and a similar critical difference (6.8 mmHg and 7.3 mmHg, respectively). We found a good correlation between ETCO2 and TcCO2, both considering the mean nocturnal PCO2 (r = 0.897, p < 0.001; bias -1.1 [- 9.0; 6.9] mmHg) and the maximal PCO2 value over the night (r = 0.905, p < 0.001; bias 3.1 [-4.5; 10.8] mmHg). The concordance of the two techniques in detecting overnight PCO2 fluctuations was high, with r = 0.919 (p < 0.001) for the time spent with PCO2 >45 mmHg and r = 0.943 (p < 0.001) for the time with PCO2 >50 mmHg. CONCLUSIONS The ventilator-integrated end-tidal CO2 monitoring is as reliable as the currently used transcutaneous measurement, resulting to be a valuable proxy of the overnight PCO2 evolution. This result opens the possibility of a simplification in the monitoring of home ventilated patients, since ETCO2 measurement can be performed directly at home, with a low additional cost. However, the accuracy of both these measurement techniques is not sufficient to replace blood gases, which remain the reference examination. ClinicalTrials.gov registration:NCT02068911.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Monitoring of end tidal carbon dioxide and transcutaneous carbon dioxide during neonatal transport.

OBJECTIVE To assess the accuracy of measurements of end tidal carbon dioxide (CO2) during neonatal transport compared with arterial and transcutaneous measurements. DESIGN Paired end tidal and transcutaneous CO2 recordings were taken frequently during road transport of 21 ventilated neonates. The first paired CO2 values were compared with an arterial blood gas. The differences between arteria...

متن کامل

بررسی همبستگی و میزان توافق نتایج PaCO2 گازهای خون شریانی با CO2 انتهای بازدمی (End-Tidal CO2) توسط کاپنوگرافی در بیماران مبتلا به تشدید حاد بیماری انسدادی ریوی (COPD)

  Background : Chronic Obstructive Pulmonary Disease (COPD) represents a major public health problem. The course of COPD is characterized by episodic periods of worsening symptoms, termed exacerbations. Supplemental oxygen should be given to patients with COPD exacerbation without causing CO2 retention. Arterial blood gas sampling is the gold standard for monitoring adequate oxygenation and for...

متن کامل

A pilot prospective study on closed loop controlled ventilation and oxygenation in ventilated children during the weaning phase

INTRODUCTION The present study is a pilot prospective safety evaluation of a new closed loop computerised protocol on ventilation and oxygenation in stable, spontaneously breathing children weighing more than 7 kg, during the weaning phase of mechanical ventilation. METHODS Mechanically ventilated children ready to start the weaning process were ventilated for five periods of 60 minutes in th...

متن کامل

The Significance of Transcutaneous Continuous Overnight CO2 Monitoring in Determining Initial Mechanical Ventilator Application for Patients with Neuromuscular Disease

OBJECTIVE To reveal the significance of continuous transcutaneous carbon dioxide (CO(2)) level monitoring through reviewing cases which showed a discrepancy in CO(2) levels between arterial blood gas analysis (ABGA) and continuous transcutaneous blood gas monitoring. METHOD Medical record review was conducted retrospectively of patients with neuromuscular diseases who had started home mechani...

متن کامل

Evaluation of a CO2 Partial Rebreathing-Based Functional Residual Capacity Measurement Method for Mechanically Ventilated Patients

There is a need for an automated bedside functional residual capacity (FRC) measurement method that can continually monitor both the size and a change in size of a patient’s lung volume during mechanical ventilation without the use of bulky equipment, expensive tracer gases or step increases in inspired oxygen fraction. We developed a CO2 rebreathing method for FRC measurement that simply requi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Respiratory medicine

دوره 117  شماره 

صفحات  -

تاریخ انتشار 2016