Influence of nonuniform activity distribution on cellular dosimetry.

نویسندگان

  • Tian Yuan
  • Zhang Liang'an
  • Dai Guangfu
چکیده

Dosimetry of nonuniformly distributed 210Po,67Cu, and 123I was evaluated for a single cell, modeled as a homogeneous unity-density sphere with a radius of 7.7 mum, which is typical of a B-cell lymphoma cell. A Visual Basic program was used to calculate S factors and radial absorbed dose-rate profiles for these radionuclides, taking into account their individual radiation energy spectra. The resulting absorbed doses were compared with those for uniform activity distributions of the respective radionuclides. It was shown that detailed radiation energy spectra are required for accurate cell-level dosimetry, especially for Auger-electron emitters. Nonuniform intracellular activity distributions do not affect the cell-to-cell S factor (i.e., S(C <-- C)) dramatically but greatly influence the cell-to-nucleus S factor (i.e., S(C <-- N)).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

When may a nonuniform distribution of 131I be considered uniform? An experimental basis for multicellular dosimetry.

UNLABELLED To varying degrees, radiopharmaceuticals are distributed nonuniformly in tissue. At a macroscopic level, the radiopharmaceutical may appear to be uniformly distributed throughout the tissue. However, on closer inspection, not all cells in the tissue may be labeled with the radiopharmaceutical. Furthermore, the radioactivity in the cells may be localized only in certain compartments w...

متن کامل

Log normal distribution of cellular uptake of radioactivity.

UNLABELLED It is widely recognized that radiopharmaceuticals are generally distributed nonuniformly in tissues. Such nonuniformities are observed over the entire range of spatial levels, ranging from organ to subcellular levels. The implications of nonuniform distributions of radioactivity for dosimetry, and ultimately for the biologic response of tissues containing radioactivity, have been inv...

متن کامل

Cellular dosimetry of beta emitting radionuclides-antibody conjugates for radioimmunotherapy

Introduction: The choice of optimal radionuclides for radioimmunotherapy depends on several factors, especially the radionuclide and antibody. The dosimetric characteristics of a non-internalizing and an internalizing monoclonal antibody (MAb) labeled with beta emitting radionuclides were investigated. Methods: Using Geant4-DNA Monte Carlo simulation, we ...

متن کامل

Lung dosimetry for radioiodine treatment planning in the case of diffuse lung metastases.

UNLABELLED The lungs are the most frequent sites of distant metastasis in differentiated thyroid carcinoma. Radioiodine treatment planning for these patients is usually performed following the Benua-Leeper method, which constrains the administered activity to 2.96 GBq (80 mCi) whole-body retention at 48 h after administration to prevent lung toxicity in the presence of iodine-avid lung metastas...

متن کامل

A Microdosimetry model of kidney for nephrotoxicity due to internal radiation therapy

Introduction: We describe a nephron-based dosimetry model for renal toxicity for radiopharmaceutical therapy suited to the nonuniform activity distribution of radiopharmaceutical. In radiopharmaceutical therapy, renal toxicity is observed while whole-kidney and renal cortex absorbed dose values are below toxicity thresholds established by external beam and targeted radiope ptid...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Cancer biotherapy & radiopharmaceuticals

دوره 23 2  شماره 

صفحات  -

تاریخ انتشار 2008