Application of paclitaxel-eluting metal stents in renal artery of pig model.
نویسندگان
چکیده
BACKGROUND AND PURPOSE Recent reports concerning coronary, carotid, and femoral vasculature have proposed the use of drug-eluting metal stents (MS) to improve clinical and angiographic outcomes. Based on these reports, we used paclitaxel-eluting MS within an animal renal artery lumen and compared the results with those using a bare-metal stent. MATERIALS AND METHODS The experimental model in this study was the female pig renal artery. Ten pigs with weights ranging from 25 to 30 kg were used. Twenty stents were placed, two in each animal. The MS placement was randomly performed in either the right or left renal artery of each animal. In 10 arteries, a 3.5 x 18 mm R-stent (group A) was placed; in the remaining 10 arteries, a 3 x 32 mm paclitaxel-eluting coronary stent (T-stent, group B) was inserted. Patency was estimated with the use of digital subtraction angiography, CT angiography, and virtual endoscopy at 24 hours and 1 month poststent placement. RESULTS The positioning of the MS was successful in all cases. The initial angiographic result was maintained 24 hours after the intervention. No stent migration was seen, except for one paclitaxel stent that was acutely occluded. The one-month patency rate, as demonstrated by angiography, CT angiography, and virtual endoscopy, was 70% (8 arteries) in group A and 90% (9 arteries) in group B. The thickness of the endothelium and of the muscular coat was statistically significantly less in group B compared with group A (P = 0.0352 and P = 0.0046, respectively). CONCLUSION These preliminary experimental study results suggest that the paclitaxel-eluting MS is more efficient than the bare-metal stent when used within the pig renal artery. Further experimental and clinical studies are necessary to validate our preliminary encouraging results.
منابع مشابه
Comparison of bare metal stent and paclitaxel-eluting stent using a novel rat aorta stent model
The purpose of our study was to create a novel rat aorta stent implantation model. Stainless steel bare metal stents (BMS) or paclitaxel-eluting stents (PES) were implanted in male Sprague-Dawley rats (BW 400 ± 20 g). Two and four weeks after stent implantation, the aorta were collected, fixed with 2% glutaraldehyde, and cut into two segments. One segment was used for scanning electron microsco...
متن کاملIntravascular ultrasonic comparative analysis of degree of intimal hyperplasia produced by four different stents in the coronary arteries.
Intravascular ultrasound studies were performed at angiographic follow-up on 121 native coronary lesions treated with 1 bare metal stent (n = 50), high-dose dexamethasone-eluting stents (n = 18), non-polymer-based paclitaxel-eluting stents (n = 18), or sirolimus-eluting stents (n = 35). Paclitaxel- and sirolimus-eluting stents reduced mean intimal hyperplasia thickness compared with bare metal ...
متن کاملApplication of paclitaxel-eluting metal mesh stents within the pig ureter: an experimental study.
OBJECTIVE The purpose of the present study is to compare the standard bare metal stents (BMS) with the Paclitaxel-Drug Eluting Stent (DES) in the ureter of a pig model. MATERIALS AND METHODS We report on an experimental study with ten female pigs weighing between 25 and 30 kg. The stents were randomly placed in either the right or left ureter in each of 10 study animals, for a total of 20 ste...
متن کاملEvaluation of a novel slow-release paclitaxel-eluting stent with a bioabsorbable polymeric surface coating.
OBJECTIVES We sought to evaluate a new second-generation drug-eluting stent (DES), comprising a slow-release biodegradable polylactide coglycolide (PLGA) polymer and low-dose paclitaxel on a thin-strut cobalt chromium stent platform, in a clinically relevant animal model. BACKGROUND Our previous work demonstrated subacute vascular toxicity and necrosis triggering late excess neointima in pig ...
متن کاملDoes the use of paclitaxel or rapamycin-eluting stent decrease further need for coronary-artery bypass grafting when compared with bare-metal stent?
CONTEXT AND OBJECTIVE The safety and efficacy of drug-eluting stents reduce the need for surgical revascularization. The objective of the present study was to investigate whether paclitaxel or rapamycin-eluting stent are effective in avoiding the need for coronary-artery bypass grafting. METHODS This was a systematic review of the literature using the methodology of the Cochrane Collaboration...
متن کاملذخیره در منابع من