Internal carotid artery stenosis measurement: comparison of 3D computed rotational angiography and conventional digital subtraction angiography.

نویسندگان

  • Derek E Hyde
  • Allan J Fox
  • Irene Gulka
  • Paul Kalapos
  • Don H Lee
  • David M Pelz
  • David W Holdsworth
چکیده

BACKGROUND AND PURPOSE Clinical trials have shown that carotid endarterectomy reduces stroke risk in symptomatic individuals with severe internal carotid artery (ICA) stenosis. As a result of these trials, digital subtraction angiography (DSA) became a standard of reference for ICA stenosis diagnosis. Newer 3D techniques provide a larger number of views than DSA, which may influence the estimated degree of stenosis. We evaluate this possibility by directly comparing stenosis grades from 3D computed rotational angiography (CRA) and DSA. METHODS As a prospective diagnostic study, we performed CRA and DSA on 26 consecutive symptomatic patients. Only 1 angiographic procedure was performed on normal asymptomatic arteries, yielding 42 arteries for comparison. Four neuroradiologists graded the CRA maximum intensity projections (MIPs) and DSA images, according to the North American Symptomatic Carotid Endarterectomy Trial guidelines. CRA studies included a search for the narrowest view by evaluating 60 MIPs generated at 3 degrees intervals and measurement of actual artery diameters. Artery diameters and stenosis grades were analyzed graphically; statistical significance was determined using a paired t test. RESULTS The mean difference of 1.2% (CI, -18%, 21%) between CRA and DSA stenosis grades was not statistically significant (P=0.55). Agreement of the optimal CRA viewing angle was limited, with an interobserver variability of 24+/-13 degrees . The interobserver variability of DSA and CRA stenosis grades, 9.1% (CI, 0%, 21%) and 9.4% (CI, 0%, 22%), respectively, was not significantly different (P=0.79). CONCLUSIONS CRA provides stenosis grades equivalent to DSA, as well as absolute measurements, providing a comparison for newer 3D techniques.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Multi-detector row CT angiography in the assessment of carotid artery disease in symptomatic patients: comparison with rotational angiography and digital subtraction angiography.

BACKGROUND AND PURPOSE Compared with the single-detector technique, multi-detector row CT angiography permits larger anatomic coverage that includes both the epiaortic and entire carotid circulations. We evaluated the accuracy of multi-detector row CT angiography by using multiplanar reformation (MPR) for measuring carotid artery diameters compared with that of rotational angiography. We also e...

متن کامل

ارزیابی و بررسی نتایج حاصل از داپلر فراصوتی در مقایسه با آنژیوگرافی تفریقی دیجیتال در تشخیص تنگ شدگیهای شریان کاروتید داخلی

Introduction: Digital Subtraction Angiography (DSA) is the standard method for detection of carotid artery stenosis. This technique has high radiation dose. With the progress of imaging techniques, noninvasive or minimally invasive methods like the CT angiography, MR angiography and ultrasonography with Doppler or Duplex mode were applicable. This study aimed to evaluate and assesse the results...

متن کامل

Radiological measurements of dimensions of acutely ruptured internal carotid artery aneurysm: a comparative study between computed tomographic angiography and digital subtraction angiography

After aneurysmal subarachnoid hemorrhage, most center practices treatment modality selection based on size and geometry in computed tomographic angiography. However, the validity as compared to digital subtraction angiography (DSA) is not well studied. Twenty patients with ruptured internal carotid artery aneurysm were identified in a two-year period. Mean difference in measurements from 3D com...

متن کامل

Simultaneous bilateral internal carotid artery 3D rotational angiography.

We simultaneously injected both internal carotid arteries (ICAs) during 3D rotational digital subtraction angiography in a patient with a ruptured anterior communicating artery (Acom) aneurysm and vasospasm. Shaded surface display (SSD) images from this acquisition provided more anatomic detail than did SSD images created from individual ICA 3D rotational digital subtraction angriography. In th...

متن کامل

Intravenous digital subtraction angiography of the nearly occluded internal carotid artery.

Three patients with nearly occluded internal carotid artery origins were evaluated with intravenous digital subtraction angiography and subsequently had successful carotid endarterectomies. The angiographic features are described. Although conventional arterial angiography offers superior spatial resolution and selectivity, the thorough mixing of blood and contrast medium that occurs with the i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Stroke

دوره 35 12  شماره 

صفحات  -

تاریخ انتشار 2004