Prevalence and predictors of electrical storm in patients with implantable cardioverter-defibrillator.

نویسندگان

  • Arash Arya
  • Majid Haghjoo
  • Mohammad Reza Dehghani
  • Amir Farjam Fazelifar
  • Mohammad-Hosein Nikoo
  • Ataollah Bagherzadeh
  • Mohammad Ali Sadr-Ameli
چکیده

Identifying predictors of electrical storm in patients with implantable cardioverter-defibrillators (ICDs) could help identify those at risk and reduce the incidence of this emergency situation, which has a detrimental effect on mortality and morbidity in patients with ICDs. This retrospective study sought to determine the prevalence and predictors of electrical storm in patients with ICDs. One hundred sixty-two patients (126 men; mean age 58 +/- 13 years) who received ICDs from January 2001 to January 2005 were included in the study. Clinical, electrocardiographic, and ICD stored data and electrograms were collected and analyzed. Twenty-two patients (14%) developed electrical storm during a mean follow-up of 14.3 +/- 10 months. Using Cox multiple regression analysis, it was found that an ejection fraction <25% (p = 0.007), QRS width > or =120 ms (p = 0.002), and a lack of adjunctive angiotensin-converting enzyme inhibitor and beta-blocker therapy (both p < 0.001) were correlated with a greater probability of electrical storm. Adjunctive amiodarone and digoxin therapy, indication of ICD implantation, and age were not correlated with the occurrence of electrical storm during follow-up (all p = NS). In conclusion, electrical storm is not uncommon in patients with ICDs. Optimum medical therapy with beta blockers and angiotensin-converting enzyme inhibitors could reduce the occurrence of electrical storm, and this especially should be considered in those at greater risk for this complication (i.e., those with left ventricular ejection fractions <25% and QRS widths > or =120 ms).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Predictors of appropriate and inappropriate Therapies in Patients with implantable cardioverter-defibrillator and Structural Heart Disease

Part 1)* Identifying predictors of electrical storm in patients with implantable cardioverter-defibrillator (ICD) could help to identify those at risk and reduce the incidence of this emergency situation which has detrimental effect on mortality and morbidity in patients with ICD. In this retrospective study we sought to find the prevalence and predictors of electrical storm in patients with IC...

متن کامل

THE EFFECT OF NURSE-PEER-LED SUPPORT INTERVENTION ON QUALITY OF LIFE IN PATIENTS WITH AN IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR: A RANDOMIZED CLINICAL TRIAL

Background & Aims: Nowadays, the quality of life and how coping and treatment of patients with an implantable cardiac defibrillator has led to concern and attempts to reduce or eliminate the problems of these patients in the people who provide health care services. This study aimed to determine the effect of nurse-peer-led support intervention on quality of life in patients with an implantable ...

متن کامل

Implantable cardioverter-defibrillator in a patient with dextrocardia situs inversus

Background: Dextrocardia is a congenital anomaly, which may have coexistent coronary artery disease (CAD), arrhythmias and conventional indications for device therapy. However, the implantation of transvenous leads can be technically challenging and the approach needs to be tailored to the patient's individual anatomy. Case presentation: A 54-year-old male with dextrocardia situs inversus and i...

متن کامل

Temporal Trends and Temperature-Related Incidence of Electrical Storm

Electrical storm (ES) is usually defined as the occurrence of ≥3 episodes of sustained ventricular tachycardia (VT) or ventricular fibrillation (VF) within 24 hours requiring either antitachycardia pacing or cardioversion/defibrillation. ES represents a true medical emergency that requires a multidisciplinary approach, and its prevalence is steadily rising along with the number of patients bear...

متن کامل

Implantable Cardioverter-Defibrillator Therapy in Brugada Syndrome

RESULTS A total of 176 consecutive patients were included. During a mean follow-up period of 83.8 57.3 months, spontaneous sustained VAs occurred in 30 patients (17%). Eight patients (4.5%) died. Appropriate ICD shocks occurred in 28 patients (15.9%), and 33 patients (18.7%) had inappropriate shocks. Electrical storm occurred in 4 subjects (2.3%). Twenty-eight patients (15.9%) experienced devic...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Archivos de cardiologia de Mexico

دوره 78 1  شماره 

صفحات  -

تاریخ انتشار 2006