BACKGROUND In high-income countries, 6% of all women will have sustained a fracture of the wrist (distal radius) by the age of 80 years and 9% by the age of 90 years. Advances in orthopaedic surgery have improved the outcome for patients: many such fractures can be treated in a plaster cast alone, but others require surgical fixation to hold the bone in place while they heal. The existing evidence suggests that modern locking-plate fixation provides improved functional outcomes, but costs more than traditional wire fixation. METHODS In this multicentre trial, we randomly assigned 461 adult patients having surgery for an acute dorsally displaced fracture of the distal radius to either percutaneous Kirschner-wire fixation or locking-plate fixation. The primary outcome measure was the Patient-Rated Wrist Evaluation© (PRWE) questionnaire at 12 months after the fracture. In this surgical trial, neither the patients nor the surgeons could be blind to the intervention. We also collected information on complications and combined costs and quality-adjusted life-years (QALYs) to assess cost-effectiveness. RESULTS The baseline characteristics of the two groups were well balanced and over 90% of patients completed follow-up. Both groups of patients recovered wrist function by 12 months. There was no clinically relevant difference in the PRWE questionnaire score at 3 months, 6 months or 12 months [difference at 12 months: -1.3; 95% confidence interval (CI) -4.5 to 1.8; p=0.398]. There was no difference in the number of complications in each group and small differences in QALY gains (0.008; 95% CI -0.001 to 0.018); Kirschner-wire fixation represents a cost-saving intervention (-£727; 95% CI -£588 to -£865), particularly in younger patients. CONCLUSIONS Contrary to the existing literature, and against the increasing use of locking-plate fixation, this trial shows that there is no difference between Kirschner wires and volar locking plates for patients with dorsally displaced fractures of the distal radius. A Kirschner-wire fixation is less expensive and quicker to perform. TRIAL REGISTRATION Current Controlled Trials ISRCTN31379280. FUNDING This project was funded by the NIHR Health Technology Assessment programme and will be published in full in Health Technology Assessment; Vol. 19, No. 17. See the NIHR Journals Library website for further project information.
منابع مشابه
Percutaneous fixation with Kirschner wires versus volar locking plate fixation in adults with dorsally displaced fracture of distal radius: randomised controlled trial
OBJECTIVES To compare the clinical effectiveness of Kirschner wire fixation with locking plate fixation for patients with a dorsally displaced fracture of the distal radius. DESIGN A multicentre two arm parallel group assessor blind randomised controlled trial with 1:1 treatment allocation. SETTING 18 trauma centres in the United Kingdom. PARTICIPANTS 461 adults with a dorsally displaced ...
متن کاملDorsally displaced fractures of the distal radius: a critical appraisal of the DRAFFT (distal radius acute fracture fixation trial) study.
The results of the DRAFFT (distal radius acute fracture fixation trial) study, which compared volar plating with Kirschner (K-) wire fixation for dorsally displaced fractures of the distal radius, were published in August 2014. The use of K-wires to treat these fractures is now increasing, with a concomitant decline in the use of volar locking plates. We provide a critical appraisal of the DRAF...
متن کاملVolar locking-plate and Kirschner-wire fixation did not differ in terms of functional outcomes after dorsally displaced distal radial fracture.
Volar locking-plate and kirschner-wire fixation did not differ in terms of functional outcomes after dorsally displaced distal radial fracture.
متن کاملVolar locking plate fixation versus Kirschner wire fixation in distal radius fractures: a meta-analysis
Objective: The superiority of volar locking plate fixation and K-wire fixation on treatment of distal radius fractures was controversial. Thus, we performed a meta-analysis to compare the efficacy of volar locking plate and K-wires for distal radius fracture. Methods: We searched Embase, Medline and PubMed for randomized controlled trials which compare the effects of volar locking plate and K-w...
متن کاملVolar locking distal radius plates show better short-term results than other treatment options: A prospective randomised controlled trial
AIM To compare the outcomes of displaced distal radius fractures treated with volar locking plates and with immediate postoperative mobilisation with the outcomes of these fractures treated with modalities that necessitate 6 wk wrist immobilisation. METHODS A prospective, randomised controlled single-centre trial was conducted with 56 patients who had a displaced radius fracture were randomis...
متن کامل