Real-time validation of transcranial Doppler criteria in assessing recanalization during intra-arterial procedures for acute ischemic stroke: an international, multicenter study.
نویسندگان
چکیده
BACKGROUND AND PURPOSE We sought to evaluate the diagnostic accuracy of ultrasound criteria for recanalization during real-time transcranial Doppler monitoring of intra-arterial reperfusion procedures in acute ischemic stroke patients in an international, multicenter study. METHODS Consecutive acute ischemic stroke patients with proximal intracranial occlusions underwent intra-arterial reperfusion procedures with simultaneous real-time transcranial Doppler monitoring at 3 tertiary-care stroke centers. Residual flow signals at the site of angiographically confirmed occlusions were monitored at a constant transtemporal insonation angle using a standard head-frame. Recanalization was assessed simultaneously by digital subtraction angiography and ultrasound using thrombolysis in myocardial infarction and thrombolysis in brain ischemia (TIBI) criteria, respectively. Independent readers blinded to digital subtraction angiography performed validation of TIBI flow grades. The interrater reliability for assessment of TIBI grades was investigated. RESULTS We evaluated time-linked real-time digital subtraction angiography transcranial Doppler images from 96 diagnostic digital subtraction angiography runs during intra-arterial reperfusion procedures in 62 acute ischemic stroke patients (mean age, 59 ± 17 years; 58% men; median baseline National Institutes of Health Stroke Scale score, 18 [interquartile range 12-21]; median time from symptom onset to intra-arterial procedure initiation, 240 minutes [interquartile range 163-308]). The interrater reliability for evaluation of TIBI grades and assessment of recanalization was good (Cohen κ: 0.838 and 0.874, respectively; P<0.001). Compared with angiography, transcranial Doppler had the following accuracy parameters for detection of complete recanalization (TIBI 4 and 5 versus thrombolysis in myocardial infarction 3, flow grades): sensitivity, 88% (95% confidence interval, 72%-96%); specificity, 89% (79%-95%); positive predictive value, 81% (65%-91%); negative predictive value, 93% (84%-98%); and overall accuracy 89% (80%-94%). CONCLUSIONS At laboratories with high-interrater reliability, TIBI criteria can accurately predict brain recanalization in real time as compared with thrombolysis in myocardial infarction angiographic scores.
منابع مشابه
Transcranial Doppler sonography monitoring of local intra-arterial thrombolysis in acute occlusion of the middle cerebral artery.
BACKGROUND AND PURPOSE The aim of this study is to report on the use of transcranial Doppler ultrasonography as a noninvasive diagnostic monitoring tool during local intra-arterial thrombolysis in a patient with acute embolic occlusion of the middle cerebral artery. CASE DESCRIPTION We describe a 41-year-old woman with mitral valve stenosis suffering from embolism of the middle cerebral arter...
متن کاملThe Findings of Transcranial Doppler Ultrasonography in Patients with Ischemic Stroke
Background: Stroke is a multifactorial disorder, the most common cause being arterial occlusion. Transcranial Doppler Ultrasonography (TCD) is a common non-invasive method available for assessment the arterial blood flow of the brain. Objective: Assessment the hemodynamic parameters of cerebral arteries, using TCD device in patients suffering ischemic stroke. Materials and Methods: This descr...
متن کاملConsensus recommendations for transcranial color-coded duplex sonography for the assessment of intracranial arteries in clinical trials on acute stroke.
BACKGROUND AND PURPOSE Transcranial color-coded duplex sonography has become a standard diagnostic technique to assess the intracranial arterial status in acute stroke. It is increasingly used for the evaluation of prognosis and the success of revascularization in multicenter trials. The aim of this international consensus procedure was to develop recommendations on the methodology and document...
متن کاملDiagnostic criteria and yield of real-time transcranial Doppler monitoring of intra-arterial reperfusion procedures.
BACKGROUND AND PURPOSE Intra-arterial (IA) rescue procedures are increasingly used to treat acute ischemic stroke. We implemented continuous transcranial Doppler (TCD) monitoring during these procedures to detect any potentially harmful flow changes. Here, we report diagnostic criteria and yield of TCD monitoring. METHODS We studied consecutive acute stroke patients who underwent IA reperfusi...
متن کاملIntra-arterial versus intra-venous thrombolysis within and after the first 3 hours of stroke onset
The NINDS trial demonstrated for the first time the effectiveness of intravenous thrombolysis in improving outcome after acute ischemic stroke. The absolute benefit of this intervention was 11-13% greater chance of being normal or near normal (MRS ≤ 1) at 3 months. However, if patients with severe stroke were considered (NIHSS ≥ 20), the absolute benefit dropped to 5-6%, indicating that IV thro...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Stroke
دوره 44 2 شماره
صفحات -
تاریخ انتشار 2013