Effect of Tidal Volume and Nebulizer Type and Position on Albuterol Delivery in a Pediatric Model of Mechanical Ventilation.

نویسندگان

  • Ariel Berlinski
  • J Randy Willis
چکیده

BACKGROUND Optimization of factors affecting aerosol delivery during mechanical ventilation in the pediatric population is important. We hypothesized that increasing the tidal volume (V(T)), using a vibrating mesh nebulizer, and placing the nebulizer at the ventilator would increase lung dose/delivery efficiency. METHODS Continuous-output jet and vibrating mesh nebulizers loaded with albuterol (2.5 mg/3 mL) were compared when placed before the Y-piece and at the ventilator. The model consisted of a ventilator operated in pressure-regulated volume control ventilation mode at a breathing frequency of 20 breaths/min, PEEP of 5 cm H2O, FIO2 of 0.4, inspiratory time of 0.75 s, and bias flow of 0.5 L/min with a humidifier (37 ± 1.5°C) and an adult heated-wired circuit. V(T) values of 100, 150, 200, and 300 mL were studied. The circuit was connected in series to a 5.5-mm inner diameter endotracheal tube with a filter (lung dose) interposed between them. Delivery efficiency was calculated as a percentage of the nominal dose captured on the filter. Albuterol content was analyzed by spectrophotometry (276 nm). RESULTS No differences in lung dose/delivery efficiency were found at different V(T) values for the jet nebulizer (both positions) and the vibrating mesh nebulizer (ventilator). Lung dose/delivery efficiency was higher (P < .02) at a VT of 100 mL compared with the other volumes tested. The vibrating mesh nebulizer had higher lung dose/delivery efficiency compared with the jet nebulizer only when placed before the Y-piece. Moving the nebulizers from before the Y-piece to the ventilator increased lung dose/delivery efficiency for all conditions tested except the vibrating mesh nebulizer at a V(T) of 100 mL (P = .36). CONCLUSIONS Optimization of inhaled drug delivery during pediatric mechanical ventilation should include careful selection of the type of delivery device and its placement in the ventilator circuit. Increasing V(T) during nebulization did not increase lung dose/delivery efficiency.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Albuterol delivery via intrapulmonary percussive ventilator and jet nebulizer in a pediatric ventilator model.

BACKGROUND In-line administration of bronchodilators is widely used in pediatric patients receiving mechanical ventilation. We compared the amount of albuterol captured at the end of the endotracheal tube (ETT) with an intrapulmonary percussive ventilator (IPV) versus a Salter 8900 jet nebulizer placed in-line in a pediatric ventilator model, under various operating conditions. We hypothesized ...

متن کامل

Influence of nebulizer type, position, and bias flow on aerosol drug delivery in simulated pediatric and adult lung models during mechanical ventilation.

BACKGROUND The effectiveness of aerosol drug delivery during mechanical ventilation is influenced by the patient, ventilator, and nebulizer variables. The impact of nebulizer type, position on the ventilator circuit, and bias flow on aerosol drug delivery has not been established for different age populations. OBJECTIVE To determine the influence of nebulizer position and bias flow with a jet...

متن کامل

Albuterol delivery by 4 different nebulizers placed in 4 different positions in a pediatric ventilator in vitro model.

BACKGROUND The type of aerosol generator and the position in the ventilator circuit are crucial to determine aerosol delivery during mechanical ventilation. We compared lung deposition of albuterol aerosols generated by 4 different nebulizers placed in-line in 4 different positions in a pediatric ventilator model. METHODS Two brands of continuously operated jet nebulizer (6 L/ min, oxygen), a...

متن کامل

Evaluation of aerosol generator devices at 3 locations in humidified and non-humidified circuits during adult mechanical ventilation.

BACKGROUND The position of the jet or ultrasonic nebulizer in the ventilator circuit impacts drug delivery during mechanical ventilation, but has not been extensively explored, and no study has examined all of the commonly used nebulizers. METHODS Drug delivery from jet, vibrating-mesh, and ultrasonic nebulizers and pressurized metered-dose inhaler (pMDI) with spacer was compared in a model o...

متن کامل

Bronchodilator delivery during simulated pediatric noninvasive ventilation.

BACKGROUND Noninvasive ventilation (NIV) is usually applied using bi-level positive airway pressure devices, and many of these devices use a single-limb patient circuit with an integrated leak port to purge the circuit of exhaled carbon dioxide. Sometimes bronchodilator therapy is indicated in pediatric patients, but there have been no studies of the optimal nebulizer position, with respect to ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Respiratory care

دوره 60 10  شماره 

صفحات  -

تاریخ انتشار 2015