Accuracy and reproducibility of semi-automated late gadolinium enhancement quantification techniques in patients with hypertrophic cardiomyopathy
نویسندگان
چکیده
BACKGROUND The presence and extent of late gadolinium enhancement (LGE) has been associated with adverse events in patients with hypertrophic cardiomyopathy (HCM). Signal intensity (SI) threshold techniques are routinely employed for quantification; Full-Width at Half-Maximum (FWHM) techniques are suggested to provide greater reproducibility than Signal Threshold versus Reference Mean (STRM) techniques, however the accuracy of these approaches versus the manual assignment of optimal SI thresholds has not been studied. In this study, we compared all known semi-automated LGE quantification techniques for accuracy and reproducibility among patients with HCM. METHODS Seventy-six HCM patients (51 male, age 54 ± 13 years) were studied. Total LGE volume was quantified using 7 semi-automated techniques and compared to expert manual adjustment of the SI threshold to achieve optimal segmentation. Techniques tested included STRM based thresholds of >2, 3, 4, 5 and 6 SD above mean SI of reference myocardium, the FWHM technique, and the Otsu-auto-threshold (OAT) technique. The SI threshold chosen by each technique was recorded for all slices. Bland-Altman analysis and intra-class correlation coefficients (ICC) were reported for each semi-automated technique versus expert, manually adjusted LGE segmentation. Intra- and inter-observer reproducibility assessments were also performed. RESULTS Fifty-two of 76 (68%) patients showed LGE on a total of 202 slices. For accuracy, the STRM >3SD technique showed the greatest agreement with manual segmentation (ICC = 0.97, mean difference and 95% limits of agreement = 1.6 ± 10.7 g) while STRM >6SD, >5SD, 4SD and FWHM techniques systematically underestimated total LGE volume. Slice based analysis of selected SI thresholds similarly showed the STRM >3SD threshold to most closely approximate manually adjusted SI thresholds (ICC = 0.88). For reproducibility, the intra- and inter-observer reproducibility of the >3SD threshold demonstrated an acceptable mean difference and 95% limits of agreement of -0.5 ± 6.8 g and -0.9 ± 5.6 g, respectively. CONCLUSIONS FWHM segmentation provides superior reproducibility, however systematically underestimates total LGE volume compared to manual segmentation in patients with HCM. The STRM >3SD technique provides the greatest accuracy while retaining acceptable reproducibility and may therefore be a preferred approach for LGE quantification in this population.
منابع مشابه
Precision and reproducibility of semi-automated late gadolinium enhancement quantification techniques in patients with hypertrophic cardiomyopathy
Background The presence and extent of hyper-enhancement (HE) on Late Gadolinium Enhancement (LGE) has been associated with adverse events in patients with Hypertrophic Cardiomyopathy (HCM). Signal-threshold techniques are routinely employed for quantification; however, the precision and reproducibility of these versus a gold standard remains uncertain. Full Width Half of Maximum (FWHM) techniqu...
متن کاملMyocardial fibrosis delineation in late gadolinium enhancement images of Hypertrophic Cardiomyopathy patients using deep learning methods
Introduction: Accurate delineation of myocardial fibrosis in Late Gadolinium Enhancement on Cardiac Magnetic Resonance (LGE-CMR) has a crucial role in the assessment and risk stratification of HCM patients. As this is time-consuming and requires expertise, automation can be essential in accelerating this process. This study aims to use Unet-based deep learning methods to automate the mentioned ...
متن کاملComparison of Semi-automated Late Gadolinium Enhancement Quantification Techniques in Measuring Septal Fibrosis in Patients with Dilated Non-Ischemic Cardiomyopathy
Background Mid-wall striae pattern late gadolinium enhancement (LGE) has been shown to independently predict future outcomes in patients with dilated non-ischemic cardiomyopathy (NICM). Standardized quantification tools are of particular interest for clinical translation of this novel imaging marker. However, signal intensity (SI) based threshold techniques, such as Signal Threshold versus Refe...
متن کاملThe extent of late gadolinium enhancement can be assessed fast and reproducible using semi-quantitative method in patients with hypertrophic cardiomyopathy
Background In hypertrophic cardiomyopathy (HCM) assessment of late gadolinium enhancement (LGE) is increasingly important as LGE has been demonstrated to be an adverse prognosticator. Manual delineation of LGE after visual assessment is labour-intensive. Automatic quantification is limited by its dependence on signal/noise ratio and varying definition of LGE. Our aim is to assess inter-individu...
متن کاملSegmental late gadolinium enhancement and gadolinium extracellular volume in hypertrophic cardiomyopathy
Background Late gadolinium enhancement (LGE) by cardiac magnetic resonance (CMR) is a common finding in patients with hypertrophic cardiomyopathy (HCM), and its extent correlates with clinical parameters such as ventricular tachycardia and sudden cardiac death. While LGE has been shown to reflect focal replacement fibrosis, recently optimized T1 mapping techniques have allowed for the quantific...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 16 شماره
صفحات -
تاریخ انتشار 2014