Relationship between ophthalmic artery blood flow and recanalization of occluded carotid artery. Ultrasonic Doppler study.
نویسندگان
چکیده
Ophthalmic artery blood flow in 5 patients with internal carotid artery occlusion of sudden onset was monitored by an ultrasonic Doppler flowmeter to investigate the possible relationship to spontaneous recanalization of the occluded artery. The occluded internal carotid arteries of 2 patients were confirmed angiographically to recanalize and the reversed flow of their ophthalmic arteries changed to physiological flow after the recanalization. The ophthalmic artery blood flow remained reversed in 2 patients whose occluded internal carotid arteries did not recanalize on the follow up angiograms. In the other patient, whose ophthalmic artery blood flow was not detected by the ultrasonic Doppler flowmeter in the acute stage, physiological flow through the ophthalmic artery was detected later. The occluded internal carotid artery did not recanalize and this physiological ophthalmic artery blood flow was filled through the circle of Willis.
منابع مشابه
Semiquantitative evaluation of ophthalmic collateral flow in carotid artery occlusion: ultrasonic doppler study.
The reliability of quantitative evaluation by doppler ultrasound with regard to the ophthalmic collateral blood flow in patients with carotid artery occlusion was estimated. The ultrasonic doppler flow signals of the ophthalmic collateral flow of 54 carotid occlusions were classified into four types and three degrees--high, moderate, and low reversed flow patterns--and were compared with the an...
متن کاملInternal carotid artery occlusion diagnosed by Doppler ultrasound.
Internal Carotid Artery Occlusion Diagnosed by Doppler Ultrasound • Using a transcutaneous Doppler ultrasonic blood velocity detector, retrograde ophthalmic artery blood flow was demonstrated in four patients, all of whom had angiographically confirmed occluded internal carotid arteries. In three, compression of the facial artery obliterated the ophthalmic artery signal. In a fourth patient com...
متن کاملPattern difference of reversed ophthalmic blood flow between occlusion and stenosis of the internal carotid artery. An ultrasonic Doppler study.
Reversed ophthalmic blood flow in the occlusions (33 patients) and stenoses (11 patients) of the internal carotid artery (ICA) was examined using the ultrasonic Doppler technique. The Doppler shift frequencies of the blood flow signal were analyzed to obtain their sound spectrogram. In stenosis of the ICA, "presystolic notch" was more frequently observed and "d/S" value (S, d; maximum blood flo...
متن کاملReversed ophthalmic artery flow in internal carotid artery occlusion. A re-appraisal based on ultrasonic Doppler investigations.
In a retrospective study, ultrasonic Doppler findings obtained with directional continuous wave equipment were evaluated in 51 patients in whom subsequently the diagnosis of an internal carotid artery occlusion was confirmed by angiography or autopsy. The evaluation was based on the registration of mean velocity analogues of medial frontal (supratrochlear) and common carotid artery blood flow. ...
متن کاملUltrasonic Doppler assessment of hemodynamics in gradual carotid ligation.
Hemodynamic changes were examined with an ultrasonic Doppler flowmeter and with a sound-spectrograph in 5 patients with internal carotid giant aneurysms or with recurrent laryngeal cancer undergoing gradual carotid occlusion. The ultrasonic Doppler technique was useful for preoperative assessment of intracranial cross-filling and as a practical guide for the graded reduction of blood flow in th...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Stroke
دوره 9 4 شماره
صفحات -
تاریخ انتشار 1978