Anatomic validation of left ventricular mass estimates from clinical two-dimensional echocardiography: initial results.

نویسندگان

  • N Reichek
  • J Helak
  • T Plappert
  • M S Sutton
  • K T Weber
چکیده

We performed a prospective anatomic validation study to determine the accuracy of left ventricular (LV) mass estimates from clinical two-dimensional echocardiographic (2-D echo) studies. In 21 subjects, antemortem 2-D echo LV mass determinations were compared with anatomic LV weight by postmortem chamber dissection. Major cardiac diagnoses included anatomic LV aneurysm in four, status post aneurysmectomy in one, transmural myocardial infarction in seven, congestive cardiomyopathy in five, rheumatic mitral disease in two, chronic severe mitral or aortic regurgitation in three, amyloid heart in two, and normal heart in three. Marked right-heart dilatation was present in 11 patients and LV thrombus in four. Regression equations derived in vitro for each 2-D echo instrument were used to correct LV mass estimates based on a short-axis, area-length method: uncorrected LV mass = 1.055 x k x 5/6 (AtLt - AcLc) + b, where At = total short-axis LV image area at the high papillary muscle level, Lc = endocardial LV length, k = an instrument-specific regression slope and b = an instrument-specific intercept. LV mass by 2-D echo correlated extremely well with actual LV weight (r = 0.93 slope = 0.85, SEE = 31 g, range 77-454 g). In contrast, M-mode echocardiographic LV mass estimates were less reliable (r = 0.86, SEE = 59 g) in these markedly distorted hearts. These 2-D echo LV mass results compare favorably with reported results from biplane angiography and M-mode echocardiography in more symmetric hearts. Thus, regression-corrected 2-D echo may be the method of choice for determining LV mass in man.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Detection of left ventricular hypertrophy by M-mode echocardiography. Anatomic validation, standardization, and comparison to other methods.

Because of its simplicity, widespread availability, relatively low cost, and lack of adverse effects, M-mode echocardiography has become the most widely used technique for measurement of human left ventricular mass. Necropsy comparison studies have yielded formulas for anatomically accurate estimation of left ventricular mass in patients with normally shaped ventricles using left ventricular me...

متن کامل

Reproducibility of left ventricular mass measurements by two-dimensional and M-mode echocardiography.

Both two-dimensional and M-mode echocardiography provide accurate estimates of left ventricular mass. However, their reproducibility in serial studies has not been compared, although this issue is critical to evaluation of regression of hypertrophy. To determine which technique provides more reproducible estimates of left ventricular mass, three serial studies were performed prospectively in ea...

متن کامل

Echocardiographic assessment of myocardial infarction: comparison of a rat model in two strains

The purpose of this study was to induce myocardial infarction (MI) and compare the echocardiographic parameters and mortality ratio of Lewis inbred and Wistar outbred strain before and after the procedure to help choose the best one for MI studies. In this study MI was induced in 46 Lewis and 34 Wistar by occlusion of left anterior descending artery (LAD). Doppler, two-dimensional (2-D) and 2-D...

متن کامل

Utility of three-dimensional echocardiography for assessment of double-orifice mitral valve.

J Am Soc Echocardiogr 2010;23:685–713. 20. Lang RM, Mor-Avi V, Sugeng L, Nieman PS, Sahn DJ. Three dimensional echocardiography: the benefits of the additional dimension. J Am Coll Cardiol 2006;48: 2053–69. 21. King DL, Gopal AS, Keller AM, Sapin PM, Schroder KM. Three-dimensional echocardiography: advances for measurement of ventricular volume and mass. Hypertension 1994;23(1 Suppl.):I172–9. 2...

متن کامل

Quantitation of human left ventricular mass and volume by two-dimensional echocardiography: in vitro anatomic validation.

21. Bennett DH, Evans DW: Correlation of left ventricular mass determined by echocardiography with vectorcardiographic and electrocardiographic voltage measurements. Br Heart J 36: 981, 1974 22. McFarland TM, Mohsin A, Goldstein S, Pickard SD, Stein PD: Echocardiographic diagnosis of left ventricular hypertrophy. Circulation 57: 1140, 1978 23. Savage DD, Drayer JIM, Henry WL, Mathews EC Jr, War...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 67 2  شماره 

صفحات  -

تاریخ انتشار 1983