Assessment of aberrations and visual quality differences between myopic and astigmatic eyes before and after contact lens application

نویسندگان

  • Mustafa Demir
  • Sevda Aydin Kurna
  • Tomris Sengor
  • Tugba Gencaga Atakan
  • Tayfun Sahin
چکیده

OBJECTIVE To evaluate the aberration and visual quality differences between myopic and astigmatic eyes before and after contact lens application by using corneal aberrometer and low- contrast sensitivity chart. METHODS Eighty eyes of 40 patients were included in this study. Patients were divided into two groups as myopic (40 eyes, n=20) and astigmatic groups (40 eyes, n=20). We used aspheric Balafilcon A (Purevision and Purevision Toric Bausch&Lomb, Rochester, USA) lenses for each group. Corneal aberrations and low-contrast sensitivity values were measured and compared for each patient in both groups. RESULTS There were no statistically significant differences between myopic and astigmatic groups when we compared low-contrast sensitivity values for both on- and off-eyes. Mean total higher-order aberration (HOA) values for off-eye, were 0.29±0.10 μm, and 0.33±0.10 μm for on-eye in the myopic group, while they were 0.42±0.14 μm in off-eye and 0.37±0.23 μm in on-eye in the astigmatic group. Off-eye mean coma, irregular astigmatism and total higher-order aberration RMS (root-mean-square) values were significantly higher in the astigmatic group compared to the myopic group (p=0.006, p=0.001, p=0.001) but mean on-eye RMS values were not. CONCLUSION Myopic and astigmatic patients differ in terms of high-order aberrations and these differences cannot be equalized after contact lens application, but visual quality can be improved in both patients by using contact lenses.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Utility of orthokeratology contact lenses; efficacy of myopia correction and level of patient satisfaction in Iranian myopic/myope-astigmatic patients

PURPOSE To investigate the medical profiles of patients referred to Iran Lens Clinic with myopic/myope-astigmatic refractive errors. METHODS Medical records of 182 patients (364 eyes) with myopic/myope-astigmatic refractive errors that underwent orthokeratology contact lens wear and fulfilled a 6-month period of follow-up were recruited. Efficacy and safety of these contact lenses in improvin...

متن کامل

Effects of optimized photorefractive keratectomy (PRK) operation on the asphericity and high-order aberration changes

Background: Optimized is a common and important method in which aberrations are created by the device and the surgeon, but high-grade aberrations are out of the surgeon's control and are induced by the device in the patient. The aim of this study was the evaluation of out-of-control high-order aberration changes before and after PRK surgery and these impact on vision outcome. Materials and meth...

متن کامل

Success rates in the correction of astigmatism with toric and spherical soft contact lens fittings

OBJECTIVES To evaluate success rates in the correction of astigmatism with toric and spherical soft contact lens fitting. METHODS 30 patients with soft toric lenses having more than 1.25 D of corneal astigmatism (25 eyes; Group A) or having 0.75-1.25 D of corneal astigmatism (22 eyes; Group B) and 30 patients with soft spheric lenses having 0.75-1.25 D of corneal astigmatism (28 eyes; Group C...

متن کامل

[Hybrid material contact lens in keratoconus and myopic astigmatism patients].

PURPOSE To evaluate comfort and visual performance in relation to two different used contact lens types: hybrid material (HM) and rigid-gas-permeable (RGP), in patients with regular myopic astigmatism and with keratoconus. METHODS A randomized, double masked, prospective study of 22 patients with the diagnosis of myopic astigmatism (8 with myopic astigmatism and 14 with keratoconus) was condu...

متن کامل

Peripheral myopization and visual performance with experimental rigid gas permeable and soft contact lens design.

PURPOSE To evaluate the performance of two experimental contact lenses (CL) designed to induce relative peripheral myopic defocus in myopic eyes. METHODS Ten right eyes of 10 subjects were fitted with three different CL: a soft experimental lens (ExpSCL), a rigid gas permeable experimental lens (ExpRGP) and a standard RGP lens made of the same material (StdRGP). Central and peripheral refract...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2  شماره 

صفحات  -

تاریخ انتشار 2015