Cuff leakage, not paravalvular leakage, in the Carpentier Edwards PERIMOUNT Magna Ease aortic bioprosthesis.
نویسندگان
چکیده
Though the Carpentier Edwards PERIMOUNT Magna Ease valve is a bioprosthesis with documented excellent haemodynamics and easy implantability, this valve has a gap between the cobalt-chromium-nickel alloy stent and silicone sewing ring. This gap, which is widest just below each of the three commissural struts, lacks silicone and leaves the two-layer polytetrafluoroethylene fabric unsupported and unprotected. If the needle of a valve suture is placed in this structurally weak area of the sewing ring, the resultant fabric tear may result in a true cuff leakage, not the usual paravalvular leakage. We describe this pitfall in the context of a recent operation to alert surgeons everywhere that suture placement too close to the stent (missing the silicone sewing ring) can result in postoperative cuff leakage. We need to be very careful to include the silicone ring in each stitch to prevent injury to the valve cuff of this prosthesis and to avoid cuff leakage.
منابع مشابه
The Carpentier-Edwards Perimount Magna mitral valve bioprosthesis: intermediate-term efficacy and durability
BACKGROUND The Carpentier-Edwards Perimount Magna mitral valve bioprosthesis (Edwards Lifesciences, Irvine, CA) is a low-profile version of the earlier Perimount valve that uses the ThermaFix process for enhanced calcium removal. The Magna valve has been in use since 2008, yet no publication, until now, has verified its intermediate-term safety and efficacy. METHODS From 2008 through 2011 (ou...
متن کاملVery long-term outcomes of the Carpentier-Edwards Perimount valve in aortic position.
BACKGROUND The Carpentier-Edwards Perimount pericardial bioprosthesis (Edwards Lifesciences, Irvine, CA) has demonstrated good long-term outcomes, but its durability remains unclear depending on age at implantation. We report our 20-year experience with the Perimount valve implanted in the aortic position, with particular attention to the probability and time to reoperation required due to biop...
متن کاملFirst dutch experience of the accurate neo self-expanding supra-annular valve for valve-in-valve transcatheter aortic valve implantation
We describe the first two cases of valve-in-valve (ViV) transcatheter aortic valve implantation (TAVI) using Accurate Neo device in the Netherlands. A 73-year-old man underwent transfemoral ViV-TAVI for severe stenosis in his 25-mm Carpentier-Edwards Perimount bioprosthesis. After balloon predilatation, a mediumsize Accurate Neo was advanced to the bioprosthetic annulus. First, its upper part w...
متن کاملEarly dysfunction of a tricuspid valve-in-valve replacement due to papillary muscle overgrowth.
We present an explantation image of an off-label transcatheter placed valve-in-valve Edwards Sapien in a Carpentier-Edwards Perimount Magna Ease aortic bioprosthesis (Edwards Lifesciences, Inc., Irvine, CA, USA) in the tricuspid position (Fig. 1). The valve was placed 1 year and 9 months before in an extremely frail patient with a complex cardiac surgical history due to an atrial septum defect ...
متن کاملThe Fluid Dynamical Performance of the Carpentier-Edwards PERIMOUNT Magna Ease Prosthesis
The aim of the present in vitro study was the evaluation of the fluid dynamical performance of the Carpentier-Edwards PERIMOUNT Magna Ease depending on the prosthetic size (21, 23, and 25 mm) and the cardiac output (3.6-6.4 L/min). A self-constructed flow channel in combination with particle image velocimetry (PIV) enabled precise results with high reproducibility, focus on maximal and local pe...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Interactive cardiovascular and thoracic surgery
دوره 21 6 شماره
صفحات -
تاریخ انتشار 2015