Left atrial volume measurement with automated border detection by 3-dimensional echocardiography: comparison with magnetic resonance imaging
نویسندگان
چکیده
OBJECTIVE Left atrial size is an important marker for adverse cardiovascular events. There is general consensus that left atrial volume index (LAVI) is the best measurement of size. The current LAVI measurement techniques are laborious. Semi-automated measurement with a 3-dimensional echocardiography (3DE) system may be a practical clinical alternative to measure LAVI, but it has not been adequately evaluated against Magnetic Resonance Imaging (MRI) gold standard. The aim of this study was to compare the accuracy of a commercially available 3D algorithm for measurement of LAVI against LAVI obtained from MRI and Area Length Method (ALM). DESIGN In 27 consecutive subjects referred for cardiac MRI (age 54 +/- 13 years, 63% male), LAVI was measured using 3 imaging modalities: 3DE, ALM, MRI and the results were correlated. ALM was measured using standard American Society of Echocardiography guidelines. The time required to measure LAVI by 3DE and ALM were compared. RESULTS There was a significant correlation in systolic and diastolic LA volumes and left atrial ejection fraction between 3DE and MRI (r = 0.86 for systole, r = 0.76 for diastole, r = 0.88 for ejection fraction, P < 0.0001 for all). There was also significant correlation of diastolic volumes between 3DE and ALM (r = 0.77, P < 0.0001). The time to obtain LAVI was shorter using 3DE versus ALM (56 +/- 8 vs 135 +/- 55 seconds, P < 0.0001). CONCLUSION Three-dimensional echocardiography with semiautomatic border detection is a practical alternative for obtaining the left atrial volume in a time-efficient manner compared to the current standard.
منابع مشابه
Quantification of left ventricular volumes and function in anesthetized beagles using real-time three-dimensional echocardiography: 4D-TomTec™ analysis versus 4D-AutLVQ™ analysis in comparison with cardiac magnetic resonance imaging
BACKROUND Real-time three-dimensional echocardiography (RT3DE) enables accurate volume determination of the left ventricle (LV), since measurements in foreshortened depicted views are avertable. Different analyzing programs are available for this RT3DE. The commonly used semi-automatic software 4D-AutLVQ™ showed underestimation of LV volumes in comparison with CMRI in healthy anesthetized dogs ...
متن کاملLeft atrial volume assessed by transthoracic three dimensional echocardiography and magnetic resonance imaging: dynamic changes during the heart cycle in children.
OBJECTIVE To assess the dynamic changes in left atrial volume by transthoracic three dimensional echocardiography and compare the results with those obtained by magnetic resonance imaging (MRI). DESIGN AND PATIENTS 30 healthy children (15 boys and 15 girls, aged 8 to 13 years) underwent examination by three dimensional echocardiography and MRI. METHODS Three dimensional echocardiography of ...
متن کاملEvaluation of diastolic function by three-dimensional volume tracking of the mitral annulus with cardiovascular magnetic resonance: comparison with tissue Doppler imaging
BACKGROUND Measurement of mitral annulus (MA) dynamics is an important component of the evaluation of left ventricular (LV) diastolic function; MA velocities are commonly measured using tissue Doppler imaging (TDI). This study aimed to examine the clinical potential of a semi-automated cardiovascular magnetic resonance (CMR) technique for quantifying global LV diastolic function, using 3D volum...
متن کاملComparison of cardiovascular magnetic resonance with real-time three-dimensional echocardiography and the right ventricular automated systolic index in the assessment of the right ventricular function
Background The right ventricular (RV) function has an important diagnostic value in many cardiopulmonary diseases and is a predictor for the long-term outcome. Cardiovascular magnetic resonance (CMR) is the gold-standard for the RV quantification as the complex anatomy of the RV, i.e. its crescentic shape, impedes reliable measurement by two-dimensional echocardiography (EC). Yet, CMR or real-t...
متن کاملUtility of three-dimensional echocardiography for assessment of double-orifice mitral valve.
J Am Soc Echocardiogr 2010;23:685–713. 20. Lang RM, Mor-Avi V, Sugeng L, Nieman PS, Sahn DJ. Three dimensional echocardiography: the benefits of the additional dimension. J Am Coll Cardiol 2006;48: 2053–69. 21. King DL, Gopal AS, Keller AM, Sapin PM, Schroder KM. Three-dimensional echocardiography: advances for measurement of ventricular volume and mass. Hypertension 1994;23(1 Suppl.):I172–9. 2...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Cardiovascular Ultrasound
دوره 7 شماره
صفحات -