Biomechanical effects of rockers on walking in a plaster cast.

نویسندگان

  • M G Hullin
  • J E Robb
چکیده

Rockers are applied to lower limb casts to assist walking but there is little information on their biomechanical effects. The performances of 10 commercially available rockers were compared. They were applied to a below-knee cast worn by a normal subject who was also tested walking in the cast alone. Gait analysis was used to evaluate kinematic and kinetic data. The design of rocker had no effect upon the kinematics of walking. However, using new criteria for kinetic assessment of rocker function (tibial floor angular velocity and centre of pressure progression), most designs had a deleterious effect on the biomechanics of gait. Only two rockers approached the ideal kinetic criteria.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Energy costs of walking in lower-extremity plaster casts.

The energy cost of walking with axillary crutches and each of three types of plaster casts (long, short, and cylinder) on the lower extremity was measured in twenty normal adult men. The knee and ankle joints were immobilized unilaterally in the neutral positions. Oxygen uptake was measured using a modified Douglas-bag technique. Heart rate, respiratory rate, and step frequency were telemetered...

متن کامل

Hexcelite versus plaster of Paris: a controlled trial of the below-knee walking cast.

Hexcelite and plaster of Paris below-knee walking casts were compared in a controlled clinical trial, involving 82 patients. Fewer bandage complications, problems and better comfort was found with Hexcelite compared to plaster of Paris (P less than 0.05). If all costs relating to materials, transportation, complications and extra visits due to these, were taken into account, plaster of Paris wa...

متن کامل

Effect of a Cast on Short-Term Reproducibility and Bone Parameters Obtained from HR-pQCT Measurements at the Distal End of the Radius.

BACKGROUND High-resolution peripheral quantitative computed tomography (HR-pQCT) is a promising tool to assess the fracture-healing process at the microscale in vivo. Since casts are often used during fracture treatment, they might affect the assessment of bone density, microarchitectural, and biomechanical parameters and the short-term reproducibility of those parameters, e.g., as a result of ...

متن کامل

Controversial Issue Session: Brace treatment in infantile scoliosis: benefits

Material and methods In 1965, Cotrel and Morel describing the EDF plaster jacket technique stated that “in young children, it should be feasible not only to prevent further progression but above all to use the child’s growth to regress structural vertebral and thoracic deformities”. Before the child start walking, we use a plaster shell in bending correction. After walking, an underarm plaster ...

متن کامل

A New Hybrid Technique for Beading and Boxing of Complete Denture Final Impressions

Introduction: The purpose of beading & boxing of an impression is to obtain an accurate cast with proper border & base thickness for fabrication of restorations. Beading is the protection of the formed border thickness of the final impressions & Boxing of an impression is building up vertical walls around it. Aim: The purpose of this hybrid technique of beading and boxing is to produce a smooth...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of bone and joint surgery. British volume

دوره 73 1  شماره 

صفحات  -

تاریخ انتشار 1991