Optimization of Ozonation Process for the Reduction of Excess Sludge Production from Activated Sludge Process of Sago Industry Wastewater Using Central Composite Design
نویسندگان
چکیده
Sago industries effluent containing large amounts of organic content produced excess sludge which is a serious problem in wastewater treatment. In this study ozonation has been employed for the reduction of excess sludge production in activated sludge process. Central composite design is used to study the effect of ozone treatment for the reduction of excess sludge production in sago effluent and to optimise the variables such as pH, ozonation time, and retention time. ANOVA showed that the coefficient determination value (R(2)) of VSS and COD reduction were 0.9689 and 0.8838, respectively. VSS reduction (81%) was achieved at acidic pH 6.9, 12 minutes ozonation, and retention time of 10 days. COD reduction (87%) was achieved at acidic pH 6.7, 8 minutes of ozonation time, and retention time of 6 days. Low ozonation time and high retention time influence maximum sludge reduction, whereas low ozonation time with low retention time was effective for COD reduction.
منابع مشابه
مقایسه کارایی فرایندهای فنتون و ازن زنی با فنتوازن زنی در کاهش لجن مازاد
Background and purpose: In activated sludge process large amounts of sludge are produced. The disposal and management of this sludge remains a big challenge due to environmental, economic, social and legal factors. Thus, selecting an appropriate process that could reduce sludge would be of great help in solving this problem. The aim of present research was to determine the effects of three pr...
متن کاملFeasibility of treating the produced sludge in municipal wastewater treatment plant using ozonation method
Background and Objective: Wastewater treatment and stabilization always imposes costs and consequently a lot of energy on wastewater treatment plants. To achieve the purification and stabilization of as much sludge as possible, breaking complex components into simpler components is considered a critical step. Therefore, this study aimed to evaluate the feasibility of treating the produced sludg...
متن کاملPrevalence of antibiotic resistant genes in selected activated sludge processes in Isfahan Province, Iran
Wastewater treatment plants are one of the main sources of dissemination of antibiotic resistance genes (ARGs) into the environment. The present study was conducted to determine the prevalence and removal of ARGs in different wastewater treatment processes. A total of 36 samples from raw and final effluent of different activated sludge processes were collected and analyzed. Molecular analysis w...
متن کاملReduction of Excess Sludge in Sewage Treatment by Ozone Application
A new process which attains both excess sludge reduction and phosphorus recovery has been developed. In this paper, characteristics of sludge solubilization by ozone were investigated in batch experiments with sludge taken from an A/O reactor supplied with synthetic sewage and several real wastewater treatment plants. Then, performance of the new developed process was investigated in a laborato...
متن کاملPharmaceutical Wastewater Chemical Oxygen Demand Reduction: Electro-Fenton, UV-enhanced Electro-Fenton and Activated Sludge
In this study, Chemical Oxygen Demand (COD) from a pharmaceutical wastewater (PhW) was reduced by several techniques such as electro-Fenton (EF), photo electro-Fenton (PEF) and activated sludge (AS) processes and the obtained data were compared with each other. The effects of several parameters such as pH, current density, H2O2/Fe2+ molar ratio, volume ratio of ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
دوره 2012 شماره
صفحات -
تاریخ انتشار 2012