Application of Long-Range Surface Plasmon Resonance for ABO Blood Typing

نویسندگان

  • Wanida Tangkawsakul
  • Toemsak Srikhirin
  • Kazunari Shinbo
  • Keizo Kato
  • Futao Kaneko
  • Akira Baba
چکیده

In this study, we demonstrate a long-range surface plasmon resonance (LR-SPR) biosensor for the detection of whole cell by captured antigens A and B on the surface of red blood cells (RBCs) as a model. The LR-SPR sensor chip consists of high-refractive index glass, a Cytop film layer, and a thin gold (Au) film, which makes the evanescent field intensity and the penetration depth longer than conventional SPR. Therefore, the LR-SPR biosensor has improved capability for detecting large analytes, such as RBCs. The antibodies specific to blood group A and group B (Anti-A and Anti-B) are covalently immobilized on a grafting self-assembled monolayer (SAM)/Au surface on the biosensor. For blood typing, RBC samples can be detected by the LR-SPR biosensor through a change in the refractive index. We determined that the results of blood typing using the LR-SPR biosensor are consistent with the results obtained from the agglutination test. We obtained the lowest detection limits of 1.58 × 105 cells/ml for RBC-A and 3.83 × 105 cells/ml for RBC-B, indicating that the LR-SPR chip has a higher sensitivity than conventional SPR biosensors (3.3 × 108 cells/ml). The surface of the biosensor can be efficiently regenerated using 20 mM NaOH. In summary, as the LR-SPR technique is sensitive and has a simple experimental setup, it can easily be applied for ABO blood group typing.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

ABO Blood-Typing Using an Antibody Array Technique Based on Surface Plasmon Resonance Imaging

In this study, readily available antibodies that are used in standard agglutination tests were evaluated for their use in ABO blood typing by a surface plasmon resonance imaging (SPR imaging) technique. Five groups of antibodies, including mixed clones of anti-A, anti-B, and anti-AB, and single clones of anti-A and anti-B, were used to construct the five-line detection arrays using a multichann...

متن کامل

Fabrication and Characterization of the Fiber Optical Taper for a Surface Plasmon Resonance Sensor

For a fiber optical surface plasmon resonance (SPR) sensor a short part of its cladding should be removed to coat a thin layer of a metal. Usually this is problematic when an optical fiber with small core diameter is used. In this paper, a new method using µliter droplet of the HF acid for short fiber optical taper fabrication is reported. Using this method in a multi-mode optical fiber w...

متن کامل

Surface Plasmon Resonance Analysis Shows an IgG-Isotype-Specific Defect in ABO Blood Group Antibody Formation in Patients with Common Variable Immunodeficiency

BACKGROUND Common variable immunodeficiency (CVID) is the most common clinically severe primary immunodeficiency and comprises a heterogeneous group of patients with recurrent severe bacterial infections due to the failure to produce IgG antibodies after exposure to infectious agents and immunization. Diagnostic recommendations for antibody failure include assessment of isoagglutinins. We have ...

متن کامل

Discrepancy in ABO Blood Grouping in a Blood Donor: A Case Report

Detection of ABO blood groups through agglutination is the basis of pre-transfusion testing. However, weak agglutination reactions may be obtained with reagent antibodies and are a result of weak expression of A and B antigens on red blood cell surface which may cause a discrepancy in blood group typing. Here, we report a donor which showed discrepancy between red blood cells (forward) and seru...

متن کامل

Surface Plasmon Resonance (SPR) biosensors based on the Kretschmann-Raether configuration, where a prism with a thin Au film deposited on one side is integrated with fluid handling

We review recent progress on the application of long-range surface plasmon-polariton waveguide biosensors for disease detection. The biosensors are constructed from metal stripe waveguides cladded in Cytop with etched microfluidic channels to expose the stripe surface to the sensing fluid. The waveguides support long-range surface plasmons in integrated optics geometries when excited in an end-...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2016  شماره 

صفحات  -

تاریخ انتشار 2016