Pooled analysis of two randomized trials comparing titanium-nitride-oxide-coated stent versus drug-eluting stent in STEMI.

نویسندگان

  • Petri O Tuomainen
  • Jussi Sia
  • Wail Nammas
  • Matti Niemelä
  • Juhani K E Airaksinen
  • Fausto Biancari
  • Pasi P Karjalainen
چکیده

INTRODUCTION AND OBJECTIVES We performed a pooled analysis based on patient-level data from the TITAX-AMI and BASE-ACS trials to evaluate the outcome of titanium-nitride-oxide-coated bioactive stents vs drug-eluting stents in patients with ST-segment elevation myocardial infarction at 2-year follow-up. METHODS The TITAX-AMI trial compared bioactive stents with paclitaxel-eluting stents in 425 patients with acute myocardial infarction. The BASE-ACS trial compared bioactive stents with everolimus-eluting stents in 827 patients with acute coronary syndrome. The primary endpoint for the pooled analysis was major adverse cardiac events: a composite of cardiac death, recurrent myocardial infarction, or ischemia-driven target lesion revascularization at 2-year follow-up. RESULTS The pooled analysis included 501 patients; 245 received bioactive stents, and 256 received drug-eluting stents. The pooled bioactive stent group was associated with a risk ratio of 0.85 for major adverse cardiac events (95% confidence interval, 0.53-1.35; P=.49) compared to the pooled drug-eluting stent group. Similarly, the pooled bioactive stent group was associated with a risk ratio of 0.71 for cardiac death (95% confidence interval, 0.26-1.95; P=.51), 0.44 for recurrent myocardial infarction (95% confidence interval, 0.20-0.97; P=.04), and 1.39 for ischemia-driven target lesion revascularization (95% confidence interval, 0.74-2.59; P=.30), compared to the pooled drug-eluting stent group. These results were confirmed by propensity-score adjusted analysis of the combined datasets. CONCLUSIONS In patients with ST-segment elevation myocardial infarction, bioactive stents were associated with lower rates of recurrent myocardial infarction compared to drug-eluting stents at 2-year follow-up; yet, the rates of cardiac death and ischemia-driven target lesion revascularization were similar.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of titanium-nitride-oxide-coated stents with zotarolimus-eluting stents for coronary revascularization a randomized controlled trial.

OBJECTIVES This study sought to compare the efficacy of passive stent coating with titanium-nitride-oxide (TiNO) with drug-eluting stents releasing zotarolimus (ZES) (Endeavor, Medtronic, Minneapolis, Minnesota). BACKGROUND Stent coating with TiNO has been shown to reduce restenosis compared with bare-metal stents in experimental and clinical studies. METHODS In an assessor-blind noninferio...

متن کامل

Long-term Outcomes of Drug-eluting versus Bare-metal stent for ST-elevation Myocardial Infarction

BACKGROUND Long-term outcomes of drug-eluting stents (DES) versus bare-metal stents (BMS) in patients with ST-segment elevation myocardial infarction (STEMI) remain uncertain. OBJECTIVE To investigate long-term outcomes of drug-eluting stents (DES) versus bare-metal stents (BMS) in patients with ST-segment elevation myocardial infarction (STEMI). METHODS We performed search of MEDLINE, EMBA...

متن کامل

Two-year follow-up after percutaneous coronary intervention with titanium-nitride-oxide-coated stents versus paclitaxel-eluting stents in acute myocardial infarction.

BACKGROUND AND AIMS The aim of this study was to evaluate the long-term effects of the titanium-nitride-oxide-coated (TITANOX) stent and the paclitaxel-eluting stent (PES) in patients who had undergone a percutaneous coronary intervention for acute myocardial infarction (MI). METHODS AND RESULTS The TITAX-AMI trial randomly assigned 425 patients with MI to receive either a TITANOX stent or a ...

متن کامل

5-year clinical outcomes after sirolimus-eluting stent implantation insights from a patient-level pooled analysis of 4 randomized trials comparing sirolimus-eluting stents with bare-metal stents.

OBJECTIVES Five-year clinical follow-up has been scheduled per protocol by the 4 Cypher (Cordis/Johnson & Johnson, Warren, New Jersey) sirolimus-eluting stent (SES) versus bare-metal stent (BMS) randomized trials. BACKGROUND A delayed arterial healing response after drug-eluting stent implantation has raised concerns about the long-term safety of drug-eluting stents. METHODS In a pooled ana...

متن کامل

Clinical long-term outcome after implantation of titanium nitride-oxide coated stents compared with paclitaxel- or sirolimus-eluting stents: propensity-score matched analysis.

AIMS We performed a propensity score matched analysis to explore whether TiNOX stents are superior to paclitaxel- (PES) and sirolimus-eluting stents (SES) in routine clinical practice. METHODS AND RESULTS A total of 1,607 patients undergoing implantation of SES, PES or TiNOX stents were prospectively entered into a stent registry and followed up for three years. Using propensity score matchin...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Revista espanola de cardiologia

دوره 67 7  شماره 

صفحات  -

تاریخ انتشار 2014