Cyclic fatigue resistance and three-dimensional analysis of instruments from two nickel-titanium rotary systems.
نویسندگان
چکیده
AIM To determine how instrument design affects the fatigue life of two nickel-titanium (Ni-Ti) rotary systems (Mtwo and ProTaper) under cyclic fatigue stress in simulated root canals. METHODOLOGY Cyclic fatigue testing of instruments was performed in stainless steel artificial canals with radii of curvature of 2 or 5 mm and an angle of curvature of 60 degrees . A total of 260 instruments were rotated until fracture occurred and the number of cycles to failure were recorded. The morphology of Ni-Ti rotary instruments was investigated by measuring the volume of millimetre slices of each instrument size starting from the tip to the shank by means of microCT analysis. The fracture surface of three representative samples of each size was analysed by scanning electron microscopy (SEM). Data were analysed by one-way anova, Holm t-test, paired t-test and linear regression; the significance was determined at the 95% confidence level. RESULTS Cycles to failure significantly decreased as the instrument volume increased for both the radii of curvature tested (P < 0.01). The radius of curvature had a statistically significant influence on the fatigue life of the instruments (P < 0.05). Larger instruments underwent fracture in less time under cyclic stress than smaller ones. SEM evaluation showed typical features of fracture through fatigue failure. CONCLUSIONS The metal volume in the point of maximum stress during a cyclic fatigue test could affect the fatigue life of Ni-Ti rotary instruments. The larger the metal volume, the lower the fatigue resistance.
منابع مشابه
Cyclic Flexural Fatigue Resistance of the Revo-s Rotary Nickel-titanium Endodontic Files
Resistance to cyclic flexural fatigue failure is an important feature of rotary nickel-titanium (NiTi) instruments. The aim of this study was to evaluate the cyclic flexural fatigue failure resistance of RevoS Shaper Universal rotary NiTi files and to compare it to two other rotary NiTi files with similar size and taper, the Hero Shaper and the ProFile. Fifteen each of Revo-S Shaper Universal, ...
متن کاملCyclic fatigue testing of three different rotary nickel titanium endodontic instruments in simulated curved canals - an in vitro sem analysis.
INTRODUCTION Instrument separation is a serious concern in endodontics. Stainless steel instruments usually deform before they separate whereas Nickel Titanium instruments do not show any sign of deformation. AIM of the present study was to compare the cyclic rotations needed to fracture three different rotary nickel titanium endodontic instruments namely Profile, K3 Endo, RaCe in simulated c...
متن کاملCyclic Fatigue of Different Nickel-Titanium Rotary Instruments: A Comparative Study
Since the introduction of nickel-titanium alloy to endodontics, there have been many changes in instrument design, but no significant improvements in the raw material properties, or enhancements in the manufacturing process. Recently, a new method to produce nickel-titanium rotary (NTR) instruments has been developed, in an attempt to obtain instruments that are more flexible and resistant to f...
متن کاملEffect of clinical use on the cyclic fatigue resistance of ProTaper nickel-titanium rotary instruments.
The resistance of ProTaper (Dentsply Maillefer, Ballaigues, Switzerland) nickel-titanium rotary instruments to cyclic fatigue was examined after their initial use in straight or curved canals in vivo. These instruments were rotated freely inside a steel phantom until separation. The number of rotations before failure and the lengths of the separated fragments were compared with data derived fro...
متن کاملFracture resistance of electropolished rotary nickel-titanium endodontic instruments.
The purpose of this study was to investigate the effect of electropolishing on cyclic flexural fatigue and torsional strength of rotary nickel-titanium endodontic instruments. Electropolished and nonelectropolished ISO size 30 (0.04 taper) EndoWave (J Morita Corporation, Osaka, Japan), ProFile (Dentsply Maillefer, Ballaigues, Switzerland), and RaCe (FKG, La-Chaux De Fonds, Switzerland) instrume...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- International endodontic journal
دوره 39 10 شماره
صفحات -
تاریخ انتشار 2006