Cervical spine motion: a fluoroscopic comparison of the AirTraq Laryngoscope versus the Macintosh laryngoscope.

نویسندگان

  • Timothy P Turkstra
  • David M Pelz
  • Philip M Jones
چکیده

BACKGROUND The optimal technique to intubate the trachea in patients presenting with a potential or documented cervical spine (C-spine) injury remains unresolved. Using continuous fluoroscopic video assessment, C-spine motion during laryngoscopy with an AirTraq Laryngoscope (King Medical Systems, Newark, DE) was compared to that with intubation using a Macintosh blade. METHODS Twenty-four healthy surgical patients gave written consent to participate in a crossover randomized controlled trial; all patients were subjected to both Macintosh and AirTraq laryngoscopy with manual inline stabilization after induction of anesthesia. The C-spine motion was examined at four areas: the occiput-C1 junction, C1-C2 junction, C2-C5 motion segment, and C5-thoracic motion segment. The time required for laryngoscopy was also measured. RESULTS C-spine motion using the AirTraq was less than that during Macintosh laryngoscopy, averaging 66% less (P < 0.01) at three of the motion segments studied, occiput-C1, C2-C5, and C5-thoracic. There was no difference at the C1-C2 segment. There was no significant difference in the time to accomplish laryngoscopy between the two devices. CONCLUSIONS For patients in whom C-spine movement is undesirable, use of the AirTraq Laryngoscope may be useful to limit movement without an increase in the duration of intubation.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Intubation biomechanics: laryngoscope force and cervical spine motion during intubation with Macintosh and Airtraq laryngoscopes.

INTRODUCTION Laryngoscopy and endotracheal intubation in the presence of cervical spine instability may put patients at risk of cervical cord injury. Nevertheless, the biomechanics of intubation (cervical spine motion as a function of applied force) have not been characterized. This study characterized and compared the relationship between laryngoscope force and cervical spine motion using two ...

متن کامل

Comparison of the C-MAC®, Airtraq®, and Macintosh laryngoscopes in patients undergoing tracheal intubation with cervical spine immobilization.

BACKGROUND We aimed at comparing the performance of the C-MAC®, Airtraq®, and Macintosh laryngoscopes when performing tracheal intubation in patients undergoing neck immobilization using manual inline axial cervical spine stabilization. METHODS Ninety consenting patients presenting for surgery requiring tracheal intubation were randomly assigned to undergo intubation using a C-MAC® (n=30), Ai...

متن کامل

Endotracheal intubation in patients with cervical spine immobilization: a comparison of macintosh and airtraq laryngoscopes.

BACKGROUND The Airtraq laryngoscope (Prodol Ltd., Vizcaya, Spain) is a novel single-use tracheal intubation device. The authors compared ease of intubation with the Airtraq and Macintosh laryngoscopes in patients with cervical spine immobilization in a randomized, controlled clinical trial. METHODS Forty consenting patients presenting for surgery requiring tracheal intubation were randomly as...

متن کامل

Prevention of Tooth and Gum Damage: Novel Application of Airtraq Laryngoscope

Conventional laryngoscopy with the Macintosh Laryngoscope has been the gold standard for tracheal intubation since 1940s.1 Failed attempts to intubate the trachea and secure airway, both in the operating room and outside, still remains a cause of anesthesia-related mortality and morbidity.2-5 Investigation is, therefore, in progress to find the best methods and/or equipment to augment the succe...

متن کامل

A comparison of tracheal intubation using the Airtraq or the Macintosh laryngoscope in routine airway management: A randomised, controlled clinical trial.

The Airtraq laryngoscope is a novel single use tracheal intubation device. We compared the Airtraq with the Macintosh laryngoscope in patients deemed at low risk for difficult intubation in a randomised, controlled clinical trial. Sixty consenting patients presenting for surgery requiring tracheal intubation were randomly allocated to undergo intubation using a Macintosh (n = 30) or Airtraq (n ...