Flow injection spectrophotometric determination of trace amounts of selenium.
نویسندگان
چکیده
A simple, rapid and sensitive flow injection spectrophotometric method for determination of selenium (0.005-1.5 mug ml(-1)) is described. The method is based on the catalytic effect of Se(IV) on the reduction reaction of thionine (TN) with sulphide ion, monitored spectrophotometrically at 598 nm. The detection limit is 5 ng ml(-1) the relative standard deviation for eight replicate measurements is 1.1% for 1 mug ml(-1) of selenium. The sampling rate is 25-30 samples h(-1). The procedure was applied successfully to the determination of selenium in real samples.
منابع مشابه
Ultra-trace Determination of Palladium(II) by Spectrophotometric Flow Injection Analysis
Nowadays, palladium compounds due to their especial characteristics used in different industries, mainly in electrical power sources and chemical productions as a catalyst. Therefore, Pd concentration is increasing in our around that can be contaminant our environment due its toxic effects. In this work, a simple, selective and rapid flow injection method of analysis (FIA) has been developed fo...
متن کاملKinetic spectrophotometric determination of trace amounts of nitrite ion using potassium bromate-murexide mixture in acidic media
A new, simple, rapid, and cheap method for determination of trace amounts of nitrite ion is reported.Determination is based on reduction of bromate ion by nitrite ion, in the presence of murexide inacidic media. During reaction of bromate ion with nitrite ion, the reaction mixture is decolorized.The absorbance changes is then monitored spectrophotometricaly at 520 nm, at 25 °C. Dynamicrange of ...
متن کاملCatalytic-Spectrophotometric Determination of Trace Amounts of Manganese(II) by Catalysis of the Oxidation of Ferroin with Periodate
A catalytic spectrophotometric method for determination of ultra-trace quantities of manganese(II) id described. The method is based on the catalytic effect of manganese(II) on the oxidation reaction of ferroin by potassium periodate in acidic media. The reaction is monitored spectrophotometrically at 510 nm by a slope method and Mn(II) is determinable in the range of 1-1000ngmL-1</sup...
متن کاملKINETIC-SPECTROPHOTOMETRIC DETERMINATION OF TRACE AMOUNTS OF NITRITE BY THE REACTION OF METHYL ORANGE FORMATION
The composite diazotization coupling reaction of sulfanilic acid and N, Ndimethylaniline was used for the precise, accurate, and rapid determination of trace amounts of nitrite ion (0.02-3 µg/ml). The reaction was monitored spectrophotometrically by measuring the absorbance of the produced methyl orange at 510 nm by a fixed the method of 5.0 minutes. The relative standard deviation for the...
متن کاملDetermination of trace amounts of bromide by flow injection/stopped-flow detection technique using kinetic-spectrophotometric method.
A simple, sensitive and selective method for the determination of bromide in seawater by using a flow injection/stopped-flow detection technique was examined. The detection system was developed for a new kinetic-spectrophotometric determination of bromide in the presence of chloride matrix without any extraction and/or separation. The detection was based on the kinetic effect of bromide on the ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Talanta
دوره 46 5 شماره
صفحات -
تاریخ انتشار 1998