Fundamental Bounds on Radio Localization Precision in the Far Field

نویسندگان

  • Bram J. Dil
  • Fredrik Gustafsson
  • Bernhard J. Hoenders
چکیده

This paper experimentally and theoretically investigates the fundamental bounds on radio localization precision of far-field Received Signal Strength (RSS) measurements. RSS measurements are proportional to power-flow measurements time-averaged over periods long compared to the coherence time of the radiation. Our experiments are performed in a novel localization setup using 2.4GHz quasi-monochromatic radiation, which corresponds to a mean wavelength of 12.5cm. We experimentally and theoretically show that RSS measurements are cross-correlated over a minimum distance that approaches the diffraction limit, which equals half the mean wavelength of the radiation. Our experiments show that measuring RSS beyond a sampling density of one sample per half the mean wavelength does not increase localization precision, as the Root-MeanSquared-Error (RMSE) converges asymptotically to roughly half the mean wavelength. This adds to the evidence that the diffraction limit determines (1) the lower bound on localization precision and (2) the sampling density that provides optimal localization precision. We experimentally validate the theoretical relations between Fisher information, Cramér-Rao Lower Bound (CRLB) and uncertainty, where uncertainty is lower bounded by diffraction as derived from coherence and speckle theory. When we reconcile Fisher Information with diffraction, the CRLB matches the experimental results with an accuracy of 97-98%.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of Ultrasound / Radio-guided Occult Lesion Localization in Non-palpable Breast Lesions

Objective(s): Controversy exists about the localization of non-palpable breast lesions. In many countries, the gold standard for the diagnosis of these lesions is needle localization due to its accuracy. This study sought to compare the ultrasoundand radio-guided occult lesion localization (ROLL) as a simple method with the conventional procedures in terms of their diagnostic power. Methods: Th...

متن کامل

Localization precision in stepwise photobleaching experiments.

The precise determination of the position of fluorescent labels is essential for the quantitative study of biomolecular structures by various localization microscopy techniques. Localization by stepwise photobleaching is especially suited for measuring nanometer-scale distances between two labels; however, the precision of this method has remained elusive. Here, we show that shot noise from oth...

متن کامل

Localization of Near Field Radio Controlled Unintended Emitting Sources

Abstract—Locating Radio Controlled (RC) devices using their unintended emissions has a great interest considering security concerns. Weak nature of these emissions requires near field localization approach since it is hard to detect these signals in far field region of array. Instead of only angle estimation, near field localization also requires range estimation of the source which makes this ...

متن کامل

A maximum-likelihood formalism for sub-resolution axial localization of fluorescent nanoparticles.

One of the ongoing challenges in single particle fluorescence microscopy resides in estimating the axial position of particles with sub-resolution precision. Due to the complexity of the diffraction patterns generated by such particles, the standard fitting methods used to estimate a particle's lateral position are not applicable. A new approach for axial localization is proposed: it consists o...

متن کامل

Using conventional fluorescent markers for far-field fluorescence localization nanoscopy allows resolution in the 10-nm range.

We present a novel technique of far-field localization nanoscopy combining spectral precision distance microscopy with widely used fluorochromes like the Green Fluorescent Protein (GFP) derivatives eGFP, EmGFP, Yellow Fluorescent Protein (YFP) and eYFP, synthetic dyes like Alexa 488 and Alexa 568, as well as fluoresceine derivates. Spectral precision distance microscopy allows the surpassing of...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • CoRR

دوره abs/1507.07385  شماره 

صفحات  -

تاریخ انتشار 2015