CALICE ScECAL Beam Test at Fermilab

نویسنده

  • Satoru Uozumi
چکیده

The scintillator-strip electromagnetic calorimeter (ScECAL) is one of the calorimeter technologies which can achieve fine granularity required for the particle flow algorithm. Second prototype of the ScECAL has been built and tested with analog hadron calorimeter (AHCAL) and tail catcher (TCMT) in September 2008 at Fermilab meson test beam facility. Data are taken with 1 to 32 GeV of electron, pion and muon beams to evaluate all the necessary performances of the ScECAL, AHCAL and TCMT system. This manuscript describes overview of the beam test and very preliminary results focusing on the ScECAL part.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Electromagnetic Calorimetry for the ILC

The CALICE Collaboration builds electromagnetic and hadronic calorimeters optimised for particle flow at ILC. Two physics prototypes for the analog electromagnetic calorimeters (ScECAL and SiW ECAL) were extensively tested with beams. Both showed a remarkable facility of operation, low noise and high stability in time. The first analysis of the testbeam data indicate that they meet the ILC requ...

متن کامل

The CALICE hadron calorimeters - test beam results

We present concepts and beam test results of highly granular calorimeter prototypes optimized for the application of particle flow algorithms. A scintillator-steel hadron calorimeter using SiPMs as photodetectors (AHCAL) has been tested in electron and hadron beams at CERN and Fermilab in the energy range 1 – 80 GeV. More than 7600 SiPMs – the highest number ever used – performed well over the ...

متن کامل

Hadronic showers in the CALICE calorimeter prototypes

The CALICE collaboration has constructed highly granular electromagnetic and hadronic calorimeter prototypes to evaluate technologies for the use in detector systems at the future International Linear Collider. These calorimeters have been tested extensively in particle beams at CERN and at Fermilab. We present preliminary results of an analysis of hadronic events in the combined system under t...

متن کامل

Readout Electronics for the Calice Ecal and Tile Hcal

The aims of the CALICE test beam program are presented. The proposed electronics readout system for the CALICE ECAL is described. It is a purposebuilt VME-based, unbuffered system. 1 The CALICE Collaboration The CALICE collaboration [1] is a group of 140 people from 24 institutes in Europe, US and Asia. The collaboration is planning a beam test program starting in 2004 to study both electromagn...

متن کامل

Analyses of test beam data using the CALICE calorimeter

We discuss several features of hadronic showers recorded in the high granularity CALICE Si-W ECAL and scintillator-tile HCAL and confront them with several Geant4 physics models. The first measurements of the time-structure of hadronic showers in a tungsten scintillator calorimeter are presented. The high granularity of the CALICE calorimeters allows a software compensation which improves the e...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009