Fixation Stability Measurement Using Two Types of Microperimetry Devices.

نویسندگان

  • Hongting Liu
  • Millena G Bittencourt
  • Raafay Sophie
  • Yasir J Sepah
  • Mostafa Hanout
  • Zubir Rentiya
  • Rachel Annam
  • Hendrik P N Scholl
  • Quan Dong Nguyen
چکیده

PURPOSE We compared the fixation stability measurements obtained with two microperimeters, the Micro Perimeter 1 (MP-1) and the Spectral OCT/SLO (OCT/SLO), in subjects with and without maculopathies. METHODS A total of 41 eyes with no known ocular diseases and 45 eyes with maculopathies were enrolled in the study. Both eyes of each participant had a 20-second fixation test using the MP-1 and OCT/SLO. The bivariate contour ellipse area (BCEA) was used for fixation stability evaluation. RESULTS In the normal group, BCEA was 2.93 ± 0.32 log minarc2 on OCT/SLO and 2.89 ± 0.30 log minarc2 on MP-1. In the maculopathy group, BCEA was 3.05 ± 0.41 log minarc2 on OCT/SLO and 3.15 ± 0.46 log minarc2 on MP-1. There was no statistically significant difference between the BCEA measured by OCT/SLO and by MP-1 in both groups. A moderate correlation was found between the two devices (r = 0.45, P < 0.001). The sample size during the fixation test was 535.5 ± 14.6 pairs of coordinates in the normal group and 530.7 ± 14.9 pairs in the maculopathy group with MP-1, while it was 72.3 ± 6.9 and 59.9 ± 10.1, respectively, with OCT/SLO. This was due to different tracking frequencies between the two microperimeters. CONCLUSION Fixation stability assessment yields similar results using the OCT/SLO and MP-1. A major difference in sampling rate between the two microperimeters does not significantly affect BCEA measurements. TRANSLATIONAL RELEVANCE Fixation stability assessments are comparable and interchangeable between the OCT/SLO and the MP-1.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Characterization of field loss based on microperimetry is predictive of face recognition difficulties.

PURPOSE To determine how visual field loss as assessed by microperimetry is correlated with deficits in face recognition. METHODS Twelve patients (age range, 26-70 years) with impaired visual sensitivity in the central visual field caused by a variety of pathologies and 12 normally sighted controls (control subject [CS] group; age range, 20-68 years) performed a face recognition task for blur...

متن کامل

Visual rehabilitation via microperimetry in patients with geographic atrophy: a pilot study

BACKGROUND Age-related macular degeneration (AMD) is the leading cause of blindness in the western world. As a consequence of AMD, patients develop structural damage that comprises the fovea and subsequently present loss of central vision, low visual acuity and unstable fixation. Contrary to what happens with anti-angiogenic treatment in neovascular AMD, there is currently no definitive treatme...

متن کامل

Feasibility of Macular Integrity Assessment (MAIA) Microperimetry in Children: Sensitivity, Reliability, and Fixation Stability in Healthy Observers.

Purpose To assess the feasibility of macular integrity assessment (MAIA) microperimetry (MP) in children. Also to establish representative outcome measures (differential light sensitivity, fixation stability, test-retest reliability) for children without visual impairment. Methods Thirty-three adults and 33 children (9-12 years) were asked to perform three monocular MAIA examinations within a...

متن کامل

Fixation stability measurement using the MP1 microperimeter.

PURPOSE The Nidek microperimeter (MP1, Nidek Instruments, Italy) is a microperimetry device that also assesses fixation stability. The MP1 does not use the method of quantifying fixation stability by calculating a bivariate contour ellipse area (BCEA). Here we compare the MP1 fixation quantification with the BCEA technique by correlating these values to various parameters of reading known to be...

متن کامل

Macular sensitivity in eyes with central serous chorioretinopathy.

PURPOSE To determine macular sensitivity and fixation characteristics in eyes with central serous chorioretinopathy (CSC) using fundus-related microperimetry. METHODS The authors reviewed 19 eyes with serous elevation within the central 10 degrees due to CSC and 15 normal healthy eyes that had undergone fundus-related microperimetry. The macular sensitivity was measured using the fundus-relat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Translational vision science & technology

دوره 4 2  شماره 

صفحات  -

تاریخ انتشار 2015