The Channel Multiplier Cathode-ray Tube

نویسندگان

  • A. W. WOODHEAD
  • D. WASHINGTON
  • D. L. LAMPORT
  • A. G. KNAPP
  • J. R. MANSELL
  • A. W. Woodhead
چکیده

This paper describes a new approach to cathode-ray tube design aimed at achieving a significant depth reduction. The addressing function of the electron beam has been separated from the light generation process by a channel electron multiplier array, allowing the use of a novel deflection system based on a low-power scanning beam. Monochrome versions of the thin tube have been made with a 12" (305 mm) picture diagonal and a front-toback depth of only 75 mm. Methods of introducing colour to the display are described, and time-sequential systems for sharing the single beam between the three primary colours are discussed. PACS numbers: 85.10.-n and 85.60.Pg.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of indoor cancer linked to accumulated radiation dose from different types of television sets in dwellings

Exposure to radiation from different types of television sets was measured to ascertain the levels of hazards posed to the human biological system. Measurement of the annual radiation dose hazards was performed using a halogen-quenched GM tube with thin mica end window having a density of 1.5 mg/cm2, effective window diameter of 0.360 inch and side wall of 0.012 inch thick. The GM tube was plac...

متن کامل

Assessment of indoor cancer linked to accumulated radiation dose from different types of television sets in dwellings

Exposure to radiation from different types of television sets was measured to ascertain the levels of hazards posed to the human biological system. Measurement of the annual radiation dose hazards was performed using a halogen-quenched GM tube with thin mica end window having a density of 1.5 mg/cm2, effective window diameter of 0.360 inch and side wall of 0.012 inch thick. The GM tube was plac...

متن کامل

بررسی اثر پاشنه آند بر دوز دریافتی بیضه‌ها در رادیوگرافی لگن

Background: Anode heel effect refers to reduction of radiation intensity in the anode side of X-ray tube. This variation in radiation intensity across the anode-cathode of X-ray tube can be benefited for decrease radiation exposure in some radiological examinations. The aim of this study was to evaluate the effect of anode heel orientation on the radiation dose received by the testes in male pa...

متن کامل

Synchronous Heart Sound Recording by Application of a Second Channel to the Cossorrobertson Cardiograph.

By using a microphone to provide the input, the standard Cossor-Robertson cardiograph can be used to record heart sounds instead of the electrocardiogram, but such a record is of little value unless it is recorded synchronously with an electrocardiogram. For this purpose two separate recording channels are necessary. The double-beam cathode ray tube with two amplifying channels has been develop...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014