Estimating the Myocardium's Angle of Three-Dimensional Trajectory, Using the Tracking of Sequential Two-Dimensional Echocardiography Images

نویسندگان

  • Mosayyeb Mobasheri
  • Manijhe Mokhtari-Dizaji
  • Faride Roshanali
چکیده

BACKGROUND In this study, the angle of the myocardium's trajectory in three dimensions (ф) was estimated by simultaneous use of long-axis and short-axis views of left ventricle septum two-dimensional images. Then correlation of three-dimensional trajectory's angle with the rotation angle from the long (χ) and short (θ) axis views was estimated and compared at the three levels of base, mid and apex of the interventricular septum wall. METHODS Two-dimensional echocardiography images of long- and short-axis views of 19 healthy men were recorded and analyzed. Using an electrocardiogram of each individual, the images of the two views were synchronized. The interventricular septum wall motion at the three levels of base, mid and apex were estimated, using a block matching algorithm throughout three cardiac cycles. Considering the defined system of coordinates and the position vectors in long and short-axis views, the 3-dimensional angle of the trajectory was calculated. RESULTS Maxima of the ф, θ, and χ angles were extracted at 16.33 ± 3.01, 10.61 ± 3.38, and 15.11 ± 3.30 degrees at base level, 22.77 ± 4.95, 7.78 ± 2.96, and 16.72 ± 2.66 degrees at mid level and 14.60 ± 5.81, 10.37 ± 5.48, and 8.79 ± 3.32 degrees at apex level, respectively, of the septum wall, respectively. This study shows significant correlation between the angle of 3-dimensional trajectory (ф) with the angle in short axis view (θ) of the septum wall at the apex level; and also with the angle in long axis view (χ) of the septum wall at base and mid levels. CONCLUSION Due to the motion of the wall of the left ventricle in three dimensions, and the non-isotropic structure of myofibers, the angle of 3-dimensional trajectory was estimated using the speckle tracking method of 2-dimentional echocardiography images.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of strain and strain rate parameters using two-dimensional speckle-tracking echocardiography in patients with coronary artery disease (Research Article)

The study aimed was to measure left ventricular (LV) strain using speckle tracking echocardiography (STE) for assessment of LV function. Eighty-two subjects (mean age 57±9 years) with suspected chest pain underwent two-dimensional (2D)-echocardiography before coronary angiography. Conventional echocardiographic parameters were used for the assessment of LV function. Longitudinal strain and its ...

متن کامل

Mandibular Dimensional Changes with aging in Three Dimensional Computed Tomographic Study in 21 to 50 Year old Men and Women

Introduction: Raising the knowledge of skeletal and soft tissue changes with aging has been highly essential due to an increasing demand for aesthetic facial surgery following aging. The aim of this study is to evaluate the three dimensional computed tomographic images and process of changes in mandible with aging. Materials and Methods: In this descriptive study, the facial CT scans were obta...

متن کامل

مقایسه تصاویر دو بعدی و سه بعدی در یادگیری درس علوم اعصاب

Background and Purpose: Using images is a requirement of medical education and evaluation of effect of type of image on learner could be helpful for medical education. The purpose of the present study is comparison of two dimensional and three dimensional images in neuroscience learning. Method: In present case control study, equal number of two dimensional and three dimensional images of neur...

متن کامل

The Role of Three Dimensional Transvaginal Ultrasound in Detection of Intrauterine Device Displacement in Post Caesarean Section: A Case Report

Intrauterine Devices (IUDs) are used as an efficient and inexpensive method of contracep¬tion. Contraceptive efficacy depends on the intrauterine location of IUD and intrauterine displacement of the IUD leads to decreased contraceptive efficacy. Expulsion of IUD and its penetration into myometrium is one of the complications of IUD. In cases where IUDs are not detected by ultrasound method, in ...

متن کامل

Visualization of a Fish Behavior Using Successive Three-Dimensional Shape Modeling

Visualization of a three-dimensional fish behavior based on the successive feature extraction using the time sequential three-dimensional shape modeling is reported. The principle of the modeling is based on the intersected viewing pyramid consisting of each image boundary of the object and the corresponding focal point. Threedirectional video images are simultaneously acquired and sequential s...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 22  شماره 

صفحات  -

تاریخ انتشار 2014