OBJECTIVE The study aimed to review pediatric intraocular lens (IOL) implantations performed in the authors' institution for the past 7 years. STUDY DESIGN The study design was a retrospective chart review. PARTICIPANTS All children who underwent IOL placement between January 1, 1989, and January 31, 1996, at ages 2 to 16 years were studied. Follow-up was a minimum of 6 months up to 4 years with an average of 13 months. INTERVENTION Placement of a primary or secondary posterior chamber IOL was performed. MAIN OUTCOME MEASURES Visual acuity and possible complications were tabulated. RESULTS Fifty-seven percent of the cataracts were caused by trauma, and 37% were infantile cataracts. Visual acuities of 20/40 or better were attained in 44% of eyes and visual acuities of 20/50 to 20/80 were attained in 27% of eyes. Visual acuities were better in children older than 4 years of age (P = 0.001). Compliance with amblyopia therapy improved vision (P = 0.004). Fibrinous membranes occurred in 41 eyes (13%), and posterior capsule opacification occurred in 120 eyes (39%). There were no significant differences in visual outcome and complications between primary and secondary implants (17%) or between capsular bag and sulcus fixation (27%). The first stable postoperative refraction was predicted accurately in most patients, based on the Sanders-Retzlaff-Kraff II (SRK II) formula and intraoperative corneal curvature and axial length determinations. The mean refraction differed from the goal by only +0.28 diopter and 84% were within +/- 2 diopters. A few patients showed large overcorrections or undercorrections. On average, no myopic shift occurred. CONCLUSIONS Short-term results of IOLs implanted in children older than 2 years of age were favorable. Visual acuities obtained were better than 20/80 in 71% despite a high prevalence (28%) of penetrating trauma. Major complications were rare.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Primary intraocular lens implantation in pediatric uveitis: a comparison of 2 populations.

OBJECTIVE To evaluate the visual outcome and postoperative complications of cataract surgery with posterior chamber intraocular lens implantation in children with uveitis. DESIGN A multicenter, retrospective, interventional case series. The setting included 3 medical centers in Israel. The interventions were cataract surgery and intraocular lens implantation. Aggressive preoperative and posto...

متن کامل

بررسی تأثیر اعمال جراحی پیوند ثانویه عدسی داخل چشمی

Background and purpose : Many aphahic patients have unfavorable vision either with glasses or contact lens. In this study Visual outcome of Seconary (I.O.L) was implantation in aphakic patients referred to Imam Hossein Haspital 1994 evaluated. Materials and Methods : In a clinical trial with sequential sampling , 30 aphakic patients (26 males , 4 females mean of age 24.4 ± 10.8 years) who...

متن کامل

Controversies in intraocular lens implantation in pediatric uveitis.

Cataract is one of the most common and visually debilitating complications of pediatric uveitis. It develops as a consequence of chronic inflammation and steroid use and is seen most often in juvenile idiopathic arthritis (JIA)-associated uveitis. Cataract extraction with intraocular lens (IOL) insertion has been carried out with a measure of success in non-uveitic pediatric eyes, but in cases ...

متن کامل

Multi-component adjustable intraocular lenses: a new concept in pediatric cataract surgery.

PURPOSE The multi-component intraocular lens (IOL) (IVO; SAS, Strasbourg, France) is a novel approach to the treatment of pediatric cataract. Because the refractive requirements for pediatric eyes often change over time, current IOL technology does not easily allow refractive adjustments after the primary surgical intervention. The multi-component IOL concept allows easy, surgical refractive ad...

متن کامل

Trypan blue-assisted posterior capsulorhexis in pediatric cataract surgery

PURPOSE To evaluate the safety and efficacy of staining the posterior capsule with trypan blue during capsulorhexis in pediatric cataract surgery. PATIENTS AND METHODS This was a prospective randomized comparative study carried out at Alpha Vision Center, Zagazig, Egypt. This study included 2 groups of children with pediatric cataract randomly allocated to undergo irrigation and aspiration. I...

متن کامل

Pediatric phakic intraocular lens surgery: review of clinical studies.

PURPOSE OF REVIEW To report on the accumulating peer-reviewed data of phakic intraocular lens (pIOL) implantation in the pediatric population. I evaluate and compare the published peer-reviewed articles for the reported efficacy and complications of phakic intraocular lens implantations in children for correction of clinically significant high refractive errors. RECENT FINDINGS Multiple studi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Ophthalmology

دوره 105 1  شماره 

صفحات  -

تاریخ انتشار 1998