Crack Monitoring Method for an FRP-Strengthened Steel Structure Based on an Antenna Sensor
نویسندگان
چکیده
Fiber-reinforced polymer (FRP) has been increasingly applied to steel structures for structural strengthening or crack repair, given its high strength-to-weight ratio and high stiffness-to-weight ratio. Cracks in steel structures are the dominant hidden threats to structural safety. However, it is difficult to monitor structural cracks under FRP coverage and there is little related research. In this paper, a crack monitoring method for an FRP-strengthened steel structure deploying a microstrip antenna sensor is presented. A theoretical model of the dual-substrate antenna sensor with FRP is established and the sensitivity of crack monitoring is studied. The effects of the weak conductivity of carbon fiber reinforced polymers (CFRPs) on the performance of crack monitoring are analyzed via contrast experiments. The effects of FRP thickness on the performance of the antenna sensor are studied. The influence of structural strain on crack detection coupling is studied through strain-crack coupling experiments. The results indicate that the antenna sensor can detect cracks in steel structures covered by FRP (including CFRP). FRP thickness affects the antenna sensor's performance significantly, while the effects of strain can be ignored. The results provide a new approach for crack monitoring of FRP-strengthened steel structures with extensive application prospects.
منابع مشابه
THEORETICAL AND NUMERICAL STUDY ON THE STRENGTHENED STEEL PLATE SHEAR WALLS BY FRP LAMINATES
In this paper, nonlinear behavior of strengthened steel plate shear walls (SPSWs) by FRP laminates theoretically and numerically has been investigated. In the first part, a new method, “the composite-plate frame Interaction (C-PFI) method”, has been introduced to predict the shear behavior of the composite steel plate shear wall systems (CSPSWs). In the second part, several models of one-story ...
متن کاملPre-Cracked Concrete Shear Strengthened with External CFRP Strips
In reinforced concrete design, there are situations where transfer of shear across a specific plane needs to be considered. Examples of such situation include corbels, bearing shoes, ledger beam bearing, and a host of connection between precast concrete elements. In this study, the shear transfer behavior of reinforced concrete is investigated experimentally by conducting test on 6 precracked p...
متن کاملCrack Detection in Fibre Reinforced Plastic Structures Using Embedded Fibre Bragg Grating Sensors: Theory, Model Development and Experimental Validation
In a fibre-reinforced polymer (FRP) structure designed using the emerging damage tolerance and structural health monitoring philosophy, sensors and models that describe crack propagation will enable a structure to operate despite the presence of damage by fully exploiting the material's mechanical properties. When applying this concept to different structures, sensor systems and damage types, a...
متن کاملFinite Element Analysis of Frp Debonding Failure at the Tip of Flexural/shear Crack in Concrete Beam
One of the most common failure modes of strengthened RC beams with externally bonded FRP is intermediate crack (IC) debonding of FRP initiated at the tip of flexural/shear cracks. This study presents a method, using extended finite element method (XFEM), to model IC debonding in an FRP-strengthened concrete beam. In XFEM, as soon as a damage initiation criterion is reached in an element, additi...
متن کاملImproving the Punching Shear Strength of RC Slabs by FRP and Steel Sheets
This paper deals with the modeling of punching shear failure in reinforced concrete slabs using nonlinear finite element analysis. The 3D finite element analyses (FEA) were performed with the appropriate modeling of element size and mesh, and the constitutive modeling of concrete. The FE numerical models are validated by comparing with the experimental results obtained from tested specimens and...
متن کامل